2007
DOI: 10.1590/s0066-782x2007000400017
|View full text |Cite
|
Sign up to set email alerts
|

Custo-efetividade dos stents recobertos por rapamicina em procedimentos percutâneos coronarianos no Brasil

Abstract: SummaryObjectives: To compare the cost-effectiveness ratios of sirolimus-eluting stents (SES) with bare-metal stents (BMS) under two perspectives: the "supplementary medical system" (health plans and private patients) and the public health (SUS) system. Methods: A decision-analytic model using three different therapeutic strategies for coronary lesions: percutaneous coronary intervention (PCI) with BMS; with SES; or with BMS followed by SES to treat symptomatic restenosis. Study endpoints were one-year event-f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0
2

Year Published

2009
2009
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 33 publications
(28 reference statements)
0
9
0
2
Order By: Relevance
“…Four studies evaluated procedures including, PCI [ 51 ], stents [ 60 , 61 ] and ICD [ 62 ]. For stents, drug-eluting early generation and new generation stents were cost-effective compared to bare metal stents [ 61 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Four studies evaluated procedures including, PCI [ 51 ], stents [ 60 , 61 ] and ICD [ 62 ]. For stents, drug-eluting early generation and new generation stents were cost-effective compared to bare metal stents [ 61 ].…”
Section: Resultsmentioning
confidence: 99%
“…For stents, drug-eluting early generation and new generation stents were cost-effective compared to bare metal stents [ 61 ]. In Brazil, though stents were not cost-effective in preventing CVD events, a sensitivity analysis showed favourable ICERs in patients with diabetes and for small vessels needing revascularization [ 60 ]. Compared to standard heart failure (HF) therapy, ICD use in those aged 60 years with HF was not cost-effective in Brazil [ 62 ].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Ampliou-se, por conseguinte, o cenário de sua aplicação em cardiologia 9 , constituindo-se em alternativa segura e eficaz no tratamento da DAC, notadamente, por reduzir, de forma significativa, a frequência de ocorrência do fenômeno da reestenose. A questão dependente do alto valor monetário agregado desses dispositivos, no entanto, tem restringido a aplicação dessa tecnologia aos pacientes tratados com ICP no Brasil 10,11 .…”
Section: O Emprego Dos Stents Farmacológicos As Operadoras De Planosunclassified
“…No Brasil, como ainda não há reembolso por parte do Sistema Único de Saúde (SUS), estima-se que essa conversão seja da ordem de 30% a 40%, concentrada em pacientes tratados pela saúde suplementar. 3,6 Diversos registros de vigilância pós-comercialização, multicêntricos, nacionais e internacionais, foram idealizados e operacionalizados no último quinquênio, aferindo as taxas de segurança (ocorrência de trombose da prótese) e eficácia (necessidade de novo procedimento de revascularização da lesão-alvo) tardias de diversas marcas e modelos de stents farmacológicos, autorizados para utilização na prática clínica pelos departamentos de vigilância sanitária de cada país. 1,2,7 O registro do stent farmacológico Nobori TM (Terumo Corporation, Tóquio, Japão) foi idealizado para confirmar a segurança e a eficácia desse dispositivo de nova geração, que difere de outros stents por apresentar polímero biodegradável e eluição do fármaco antiproliferativo biolimus A9.…”
unclassified