2019
DOI: 10.1016/j.snb.2018.09.120
|View full text |Cite
|
Sign up to set email alerts
|

CuMnO2 nanoflakes as pH-switchable catalysts with multiple enzyme-like activities for cysteine detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
29
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 70 publications
(36 citation statements)
references
References 46 publications
2
29
0
Order By: Relevance
“…As for the detection of GSH, the values of σ, k and LOD (H 2 O 2 ) are 4.9 × 10 −4 , 0.01539 and 95.52 nM, respectively. The published results about GSH and H 2 O 2 detection using the enzymatic-like activity of the peroxidase mimics are listed in Tables S1 and S2 [ 37 , 39 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 ]. It can be deduced from Tables S1 and S2 that the hybrid nanoflowers represent a satisfactory limit of detection as well as a wide linear range when detecting GSH and H 2 O 2 as compared with other peroxidase mimics.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…As for the detection of GSH, the values of σ, k and LOD (H 2 O 2 ) are 4.9 × 10 −4 , 0.01539 and 95.52 nM, respectively. The published results about GSH and H 2 O 2 detection using the enzymatic-like activity of the peroxidase mimics are listed in Tables S1 and S2 [ 37 , 39 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 ]. It can be deduced from Tables S1 and S2 that the hybrid nanoflowers represent a satisfactory limit of detection as well as a wide linear range when detecting GSH and H 2 O 2 as compared with other peroxidase mimics.…”
Section: Resultsmentioning
confidence: 99%
“…In this work, the selectivity of the detection system towards GSH was investigated by adding various interference species. As illustrated in Figure 10, no obvious change in the value of ΔA can be observed after adding the above-mentioned interference sub- GSH and H2O2 detection using the enzymatic-like activity of the peroxidase mimics are listed in Tables S1 and S2 [37,39,[60][61][62][63][64][65][66][67][68][69][70][71][72][73][74][75][76]. It can be deduced from Tables S1 and S2 that the hybrid nanoflowers represent a satisfactory limit of detection as well as a wide linear range when detecting GSH and H2O2 as compared with other peroxidase mimics.…”
Section: The Effect Of Interferences Species On the Detection Systemmentioning
confidence: 94%
See 1 more Smart Citation
“…Meanwhile, the kinetic parameters of SuO x ‐like activity of P‐MoO 3 −x NPs were measured based on the Michaelis–Menton model and Lineweaver–Burk equation, and the results were listed in Table S3 in the Supporting Information. P‐MoO 3 −x NPs have a higher K m (0.12 × 10 −3 m ) value towards sulfite than human SuO x ( K m (SO 3 2− ) = 0.017 × 10 −3 m ), demonstrating its lower affinity for sulfite as substrate.…”
Section: Resultsmentioning
confidence: 99%
“…Moreover, the concentration of detectible VB1 was 0.67 µg mL −1 with a good linear range within 0.67–202.38 µg mL −1 (0.2–600 × 10 −3 m , R 2 = 0.997). The limit of detection (LOD, S/N = 3) for VB1 was 0.46 µg mL −1 . Despite various analytic techniques have been carried out for the detection of VB1, such as high performance liquid chromatography (HPLC), spectrofluorimetric, and electrochemical methods, the unstable signal, complicated and high cost of operation limit their practical applications.…”
Section: Resultsmentioning
confidence: 99%