CsI(Tl) photon detector with PIN photodiode readout for a Kμ3 T-violation experiment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2000
2000
2020
2020

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…Long-term performance of EJ500 in this context remains to be evaluated, but it is expected to be superior for reasons predefined. On the other hand, it is known that crystals can suffer from radiation damage during in-beam operation, leadinf to the formation of color centres 9.0 ± 0.5 6.7 ± 0.5 6.5 ± 0.7 6.1 ± 0.3 6.8 ± 0.2 5.0 ± 0.3 5 170 8.0 ± 0.4 6.9 ± 0.7 6.3 ± 0.3 2.0 ± 0.1 3.9 ± 0.2 1.6 ± 0.2 6 170 8.5 ± 0.6 7.7 ± 1.0 6.9 ± 0.3 2.9 ± 0.1 2.3 ± 0.1 0.9 ± 0.1 reducing light transmission, which results in a decrease of the photon yield and therefore in a light uniformity deterioration [19,17]. However, changes in light yield and light output degradations related with radiation damage are not expected due to the short running periods and low radiation level of the R 3 B experiments [3].…”
Section: Methods Results and Data Analysismentioning
confidence: 99%
“…Long-term performance of EJ500 in this context remains to be evaluated, but it is expected to be superior for reasons predefined. On the other hand, it is known that crystals can suffer from radiation damage during in-beam operation, leadinf to the formation of color centres 9.0 ± 0.5 6.7 ± 0.5 6.5 ± 0.7 6.1 ± 0.3 6.8 ± 0.2 5.0 ± 0.3 5 170 8.0 ± 0.4 6.9 ± 0.7 6.3 ± 0.3 2.0 ± 0.1 3.9 ± 0.2 1.6 ± 0.2 6 170 8.5 ± 0.6 7.7 ± 1.0 6.9 ± 0.3 2.9 ± 0.1 2.3 ± 0.1 0.9 ± 0.1 reducing light transmission, which results in a decrease of the photon yield and therefore in a light uniformity deterioration [19,17]. However, changes in light yield and light output degradations related with radiation damage are not expected due to the short running periods and low radiation level of the R 3 B experiments [3].…”
Section: Methods Results and Data Analysismentioning
confidence: 99%
“…1. Because of the rotational symmetry of the 12 identical gaps in the spectrometer and the large directional acceptance of the photon detector [15], distortions of the K π2γ spectra due to instrumental misalignment, if any, were drastically reduced.…”
Section: Methodsmentioning
confidence: 99%
“…We detected both of the π 0 decay gammas which enabled us to reconstruct the complete kinematics of a K l3 event in contrast to the previous experiment [8]; this increased the reliability of the event selection. Because of the rotational symmetry of the 12 identical gaps in the spectrometer and the large directional acceptance of the π 0 detector [9], distortions due to detector acceptance were drastically reduced. Moreover, the similarity of the K µ3 and K e3 kinematics reduced the systematic error due to the imperfect reproducibility of the experimental conditions in the simulation of the ratio of the calculated acceptance for the K µ3 and K e3 decays.…”
Section: Methodsmentioning
confidence: 99%