2020
DOI: 10.1016/j.tust.2020.103407
|View full text |Cite
|
Sign up to set email alerts
|

Crushing strength of concrete rings with a polyurea reinforce system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(12 citation statements)
references
References 23 publications
0
11
0
Order By: Relevance
“…It is also possible to isolate the concrete structures against the impact, chemical corrosion, fire, etc. In the case of applying this coating at high thicknesses (more than 5 mm), the structures can be strong against the dynamic and static loads 37 . The remarkable and high ability of polyurea coatings to absorb energy compared to other similar construction industry coatings is a great advantage.…”
Section: Polyurea Coatings and Liningsmentioning
confidence: 99%
See 1 more Smart Citation
“…It is also possible to isolate the concrete structures against the impact, chemical corrosion, fire, etc. In the case of applying this coating at high thicknesses (more than 5 mm), the structures can be strong against the dynamic and static loads 37 . The remarkable and high ability of polyurea coatings to absorb energy compared to other similar construction industry coatings is a great advantage.…”
Section: Polyurea Coatings and Liningsmentioning
confidence: 99%
“…It can also reduce the deviation of the RC panels consisting of the polyurea coating, and it causes a significant reduction in the cracking in the concrete with polyurea coating. In this regard, Szafran and Matusiak 37 evaluated the resistance against the crushing in the reinforced concrete rings with polyurea coating. They performed a crushing strength test on these rings and discussed the failure mechanisms of the concrete specimens according to the application of polyurea coating.…”
Section: Polyurea Coatings and Liningsmentioning
confidence: 99%
“…In most cases, seismic failures in structures are triggered by their limited resilience owing to deficient component size, material properties, and lack of structural flexibility or ductility [3,4]. When subjected to earthquake loadings, brittle construction materials such as unreinforced concrete and unreinforced masonry (URM) do not display sufficient ductility [5,6]. As a result, engineers have identified retrofitting URM-based structures as a critical challenge that should be resolved.…”
Section: Introductionmentioning
confidence: 99%
“…Polyurea and polyurethane–polyurea hybrids are usually used as a podium deck and foundation wall waterproofing. However, there are many more applications, such as roof coatings, pipe protection, secondary containers, bridge deck waterproofing, tank liners, automotive industry, pool coatings, and many more [ 5 , 6 , 7 ]. Thanks to continuous material development, the number of applications is growing.…”
Section: Introductionmentioning
confidence: 99%