2016
DOI: 10.1002/elan.201600635
|View full text |Cite
|
Sign up to set email alerts
|

Crown Ether/Carbon Nanotubes Based Biperiden Disposable Potentiometric Sensor

Abstract: Sensitive disposable sensors have been constructed for potentiometric determination of Biperiden hydrochloride (BPHCl) based on multi‐walled carbon nanotubes–polyvinylchloride (MWNTs–PVC) composite in presence of dibenzo 24‐crown‐8‐ ether as a molecular receptor. Electrode matrix composition was optimized on the basis of the nature of the electroactive material, ionic sites, membrane plasticizer, and nanomaterial. The fabricated sensors showed improved selectivity and sensitivity towards biperiden hydrochlorid… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 38 publications
(45 reference statements)
0
7
0
Order By: Relevance
“…A new kinetic-potentiometric method for the characterization and analytical determination of competitive reversible enzyme inhibitors was developed [36]. Regarding other tested pharmaceutical compounds, only polyvinylchloride (PVC) sensors were found for donepezil [37], ipratropium [38,39] or biperdien [40,41]. The sited methods were linear in the concentration range from 10 -6 to 10 -2 mol L -1 of the corresponding drugs.…”
Section: Resultsmentioning
confidence: 99%
“…A new kinetic-potentiometric method for the characterization and analytical determination of competitive reversible enzyme inhibitors was developed [36]. Regarding other tested pharmaceutical compounds, only polyvinylchloride (PVC) sensors were found for donepezil [37], ipratropium [38,39] or biperdien [40,41]. The sited methods were linear in the concentration range from 10 -6 to 10 -2 mol L -1 of the corresponding drugs.…”
Section: Resultsmentioning
confidence: 99%
“…Biperiden is used to treat Parkinsonism. The findings demonstrated improved response time, lifetime, sensitivity, selectivity, and the possibility of miniaturization of the sensor compared with γ-cyclodextrins, calixarenes, and buckminsterfullerene C 60 [71].…”
Section: Disposable Potentiometric Sensormentioning
confidence: 98%
“…By applying the calibration line, it is possible to determine BIP concentrations in different samples in a range of 0.035-35.940 µmol dm -3 . When the determination range of the proposed method is compared with the methods presented in the Introduction section dealing with BIP determination in biological samples, one can see either it is at the upper limit of sensitivity [2][3][4][5] or the method is more sensitive for the same order of magnitude [6,7]. On the other hand, when compared with the methods for BIP determination in pharmaceutical formulations [8,9], the proposed procedure is capable to determine BIP in concentrations lower by 30 to 100 times, while in regard to the described spectrophotometric method [10], it is even 5000-fold more sensitive.…”
Section: Figure 2 Dixon's Diagram Of the Initial Enzymatic Reaction mentioning
confidence: 99%
“…Determination of BIP in human serum by liquid chromatography -electrospray ionization/mass spectrometry (ESI/MS), with an on-line sample clean-up procedure used, showed the limit of detection of 0.003 μmol dm -3 and determination range of 0.035-1.92 μmol dm -3 [5]. Sensitive disposable sensors have been constructed for potentiometric determination of BIP hydrochloride in dosage formulations and biological fluids, based on a multi-walled carbon nanotubes -polyvinylchloride (MWNTs-PVC) composite in the presence of dibenzo 24-crown-8-ether as a molecular receptor [6]. The method had the sensitivity range of 1-10000 μmol dm -3 , with the limit of detection of 0.1 μmol dm -3 [6].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation