2022
DOI: 10.1021/acs.analchem.2c01373
|View full text |Cite
|
Sign up to set email alerts
|

CRISPR-Cas12a-Derived Photoelectrochemical Biosensor for Point-Of-Care Diagnosis of Nucleic Acid

Abstract: This work presented a point-of-care (POC) photoelectrochemical (PEC) biosensing for the detection of human papillomavirus-16 (HPV-16) on a portable electrochemical detection system by using CRISPR-Cas12a trans-cleaving the G-quadruplex for the biorecognition/amplification and a hollow In2O3–In2S3-modified screen-printed electrode (In2O3–In2S3/SPE) as the photoactive material. G-quadruplexes were capable of biocatalytic precipitation (H2O2-mediated 4-chloro-1-naphthol oxidation) on the In2O3–In2S3/SPE surface, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
110
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 253 publications
(127 citation statements)
references
References 27 publications
(30 reference statements)
1
110
0
Order By: Relevance
“…Various such types of nanomaterials have been used for this purpose, for example, gold, graphene, nanotubes, nanodiamonds, quantum dots, and some polymeric nanoparticles. 34 , 35 …”
Section: Introductionmentioning
confidence: 99%
“…Various such types of nanomaterials have been used for this purpose, for example, gold, graphene, nanotubes, nanodiamonds, quantum dots, and some polymeric nanoparticles. 34 , 35 …”
Section: Introductionmentioning
confidence: 99%
“…In comparison to commercially available ELISA kits, the IPPBA protocol was found to be able to consistently reflect cTn I levels in plasma with t exp values < 2.78 for all test results. [46][47][48][49] Standard doses of cTnI (2 and 20 ng mL -1 ) were administered to the above series of plasma samples, and secondary tests were performed to assess the recovered cTn I levels, as shown in Figure 6D. The results of the seven sets of tests were calculated and the recoveries of the real samples were above 90% for all the tested samples, whether at high or low concentrations, and for the low concentration samples the recoveries could reach above 95%.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the reading process cannot be displayed in real-time similar to the workstation interface. Recently, with the upgrading of application software, the smartphone plays a pivotal role in the fields of molecular diagnosis, food safety, biosecurity, and environmental monitoring [7][8][9][10]. Smartphones provide many excellent functions for mobile modes, such as touch screens, wireless transmission, programmability, and data storage, which stimulate the upsurge of peripheral devices related to smartphones.…”
Section: Introductionmentioning
confidence: 99%