Crevice corrosion in orthopedic implant metals

Abstract: SummaryStudies of orthopedic implant alloys in crevice configuration suggest that cobalt-chromium alloys such as Haynes-Stellite 25 are the best choice for multicomponent implants. It is also shown that severe crevice attack may result from use of mixed metals.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0
1

Year Published

1978
1978
2014
2014

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 66 publications
(17 citation statements)
references
References 15 publications
0
16
0
1
Order By: Relevance
“…If the oxide layer in this crevice environment is damaged, there may not be sufficient oxygen or oxygen-containing species available to repassivate the surface. The aqueous microenvironment in the crevice may then, under certain situations, become acidic (pH 1 to 3), leading to further damage to the passivation layer and corrosion [11,13,15].…”
Section: Contents Lists Available At Sciencedirectmentioning
confidence: 99%
See 1 more Smart Citation
“…If the oxide layer in this crevice environment is damaged, there may not be sufficient oxygen or oxygen-containing species available to repassivate the surface. The aqueous microenvironment in the crevice may then, under certain situations, become acidic (pH 1 to 3), leading to further damage to the passivation layer and corrosion [11,13,15].…”
Section: Contents Lists Available At Sciencedirectmentioning
confidence: 99%
“…In the intervening decades, multiple avenues of research have elucidated the chemistry of corrosion, with the most common modes of concern to orthopaedic surgeons including galvanic corrosion [7,8], fretting corrosion [9][10][11][12], crevice corrosion [13][14][15], pitting corrosion [16], and intergranular corrosion [17] (Table 1).…”
Section: Modular Taper Junction Corrosionmentioning
confidence: 99%
“…Bioinert metal alloys (Ti6Al4V, Co-Cr and others) have been used as implant materials because they can support loads while provoking only minor reactions in the body [1][2][3][4][5]. The degree of the reactions can vary depending not only on intrinsic properties of bioinert materials but also on the site of implantation, degree of trauma and implant fit [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…Such particles can lead to an inflammatory tissue reaction with the formation of necrosis, granulation and fibrous tissue. Most research on these aspects goes back to the seventies and eighties of the last century [8,9].…”
Section: Do Implants Need To Be Removed Because They Damage Health?mentioning
confidence: 99%