1997
DOI: 10.1002/mrm.1910370410
|View full text |Cite
|
Sign up to set email alerts
|

Coronary flow and coronary flow reserve measurements in humans with breath‐held magnetic resonance phase contrast velocity mapping

Abstract: Objective evidence for coronary lesion significance can be obtained with ischemic stress testing. Since flow-limiting stenoses have already undergone compensatory vasodilatation to maintain flow, the response to vasoactive stimulation is dampened. The degree of response limitation is reflected by the coronary flow reserve (CFR). Absolute volume flow rates can be accurately and noninvasively measured with MRI techniques. The purpose was to assess the ability to measure coronary volume flow rate noninvasively, a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
38
0

Year Published

1999
1999
2005
2005

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(39 citation statements)
references
References 37 publications
1
38
0
Order By: Relevance
“…In 1993 Edelman et al (2) demonstrated for the first time that blood flow velocity can be determined noninvasively in human coronary arteries with MR, however, only a single mid diastolic value was obtained (2). Since then, the technique has been optimized and compared with invasive measurements of flow or flow reserve (3,5,7,25,26). Most previous investigators have used breath-hold techniques for noninvasive flow measurements.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In 1993 Edelman et al (2) demonstrated for the first time that blood flow velocity can be determined noninvasively in human coronary arteries with MR, however, only a single mid diastolic value was obtained (2). Since then, the technique has been optimized and compared with invasive measurements of flow or flow reserve (3,5,7,25,26). Most previous investigators have used breath-hold techniques for noninvasive flow measurements.…”
Section: Discussionmentioning
confidence: 99%
“…The utilization of phased array coils will improve signal-to-noise ratio, allow higher spatial resolution and make the analysis of the circumflex artery possible. Improved magnets will enable the routine use of echoplanar imaging techniques, which have already been shown to allow flow measurements in small vessels with high temporal resolution (25). A further optimization of navigator techniques will decrease scan time without loss of image quality (34).…”
Section: Further Improvementsmentioning
confidence: 99%
“…Consequently, the acquisi tion can be performed in seconds instead of min utes, with high temporal and spatial resolution [60][61][62][63][64]. If velocity-encoding gradients are added to the regular sequence, the flow velocity can be measured rapidly.…”
Section: Rapid Magnetic Resonance Phase Velocity Mappingmentioning
confidence: 99%
“…TGE has shown better flow behavior and is, therefore, more promising for reliable ultrafast flow quantification with relatively disturbed flow and significant vessel motion (e.g., coronary arteries). 9,10,14,20,25 In addition, previous in vitro and clinical studies 2,10,11,14,19,20,23,25,28,29 evaluating both EPI and TGE techniques for PVM have indicated that TGE is generally superior in terms of temporal and (sub-millimeter…”
Section: Introductionmentioning
confidence: 99%