2001
DOI: 10.1002/ccd.1088
|View full text |Cite
|
Sign up to set email alerts
|

Coronary angiography using 4 Fr catheters with acisted power injection: A randomized comparison to 6 Fr manual technique and early ambulation

Abstract: Coronary angiography using 4 Fr catheters may reduce access site complications, promote better utilization of outpatient facilities, but at a cost of suboptimal image quality. To determine whether 4 Fr diagnostic angiography with power injection (Acist, Minneapolis, MN) was equivalent to 6 Fr manual technique, 101 unselected patients were randomized to transfemoral coronary angiography with 4 or 6 Fr catheters. Procedural characteristics, angiographic quality scores, and results of 90 min ambulation were analy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
28
0

Year Published

2001
2001
2011
2011

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 21 publications
(29 citation statements)
references
References 3 publications
1
28
0
Order By: Relevance
“…However, the use of smaller catheters (Յ5F) has been limited by variable and suboptimal catheter handling and angiographic image quality using the traditional manual injection technique [4,5]. A recent trial in our laboratory comparing safety, image quality, and early ambulation between the 6F manual technique and the 4F powerassisted technique demonstrated equivalency for both image quality and ambulation times with the 4F catheters [6]. In addition, less radiographic contrast was used for patients in the 4F group.…”
Section: Introductionmentioning
confidence: 96%
See 2 more Smart Citations
“…However, the use of smaller catheters (Յ5F) has been limited by variable and suboptimal catheter handling and angiographic image quality using the traditional manual injection technique [4,5]. A recent trial in our laboratory comparing safety, image quality, and early ambulation between the 6F manual technique and the 4F powerassisted technique demonstrated equivalency for both image quality and ambulation times with the 4F catheters [6]. In addition, less radiographic contrast was used for patients in the 4F group.…”
Section: Introductionmentioning
confidence: 96%
“…Operator preference for precise control of the speed and volume of contrast delivery by the operator can be achieved instantaneously with a manually variable power injector. Contrast delivery through small catheters with this injection system has overcome the limitations of both manual and fixed power injection systems in providing adequate artery opacification through small catheters [6]. However, it is unknown whether vigorous manual contrast injection could produce coronary angiographic images equivalent to those of power injection.…”
Section: Introductionmentioning
confidence: 98%
See 1 more Smart Citation
“…4 Fr) and reduce patient contrast dose and fluoroscopy time [7,8]. They allow for monitoring of pressure at the catheter tip and have the inbuilt safety feature of response to the intensity of the operator's pressure on the control handle.…”
Section: Discussionmentioning
confidence: 99%
“…The contribution by Khoukaz et al [1] describes a study of using small-and smaller-size catheters for coronary angiography. A mechanical injector is used for the smaller catheters.…”
mentioning
confidence: 99%