2004
DOI: 10.1016/j.tiv.2004.04.005
|View full text |Cite
|
Sign up to set email alerts
|

Corneal permeability in a redesigned corneal holder for the bovine cornea opacity and permeability assay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…In line with our results with 30% TCA (No. 5), others also did not detect permeability after a 10minute treatment (13). Concerning No.…”
Section: Technical Proficiency and Reliabilitymentioning
confidence: 94%
See 1 more Smart Citation
“…In line with our results with 30% TCA (No. 5), others also did not detect permeability after a 10minute treatment (13). Concerning No.…”
Section: Technical Proficiency and Reliabilitymentioning
confidence: 94%
“…a nearby slaughterhouse, can be easily found. Possibly due to these various reasons, the BCOP test has been more often used for assessing eye irritation within the last decade (10)(11)(12)(13)(14)(15)(16) than the ICE test (17).…”
Section: Introductionmentioning
confidence: 99%
“…The holder used consisted of a Plexiglas structure, with a donor and a receiving compartment, respectively, on the epithelial and on the endothelial side of the cornea, which must be placed in the orifice, which divides the two compartments as reported by Gallarate et al [ 30 ]. To minimize the irritation caused to the cornea by the holder itself, according to the literature [ 42 ], the Plexiglas structure O-ring clamped the scleral ring all around the corneal circumference; moreover, the holder structure allowed maintaining the natural cornea curvature. The area available for diffusion was 0.63 cm 2 .…”
Section: Methodsmentioning
confidence: 99%
“…Considering eye damage and the testing of potential eye irritation can be assessed by different in vitro studies, three different categories are considered. The first category comprises organotypic test methods such as the bovine cornea opacity permeability (BCOP) test and the isolated chicken eye (ICE) test [70]. The second one englobes cytotoxicity/cell function methods as the fluorescein leakage (FL) test that studies the increase in permeability of sodium fluorescein and evaluates the toxic response in specific kidney cells and the short time exposure (STE) test that resorts to a corneal cell line from rabbit to evaluate the cytotoxic response [71].…”
Section: General Requirements For the Assessment Of Toxicological Datamentioning
confidence: 99%