“…LDL Oxidation Assays-LDL lipid peroxides were measured using the method of El-Saadani et al (48). LDL (50 -150 g of protein), in a volume of no more than 100 l, was added to 1 ml of color reagent (0.2 M KH 2 PO 4 , 0.12 M KI, 0.15 mM NaN 3 , 2 g of Triton X-100/liter, 0.1 g of benzalkonium chloride/liter, 10 M ammonium molybdate, 20 M BHT, 25 M EDTA, pH 6.2) and incubated in the dark for 30 min at room temperature; light absorbance at 365 nm was then measured and lipid peroxides were quantified by comparison with a H 2 O 2 standard curve.…”
Section: Methodsmentioning
confidence: 99%
“…LDL Oxidation Assays-LDL lipid peroxides were measured using the method of El-Saadani et al (48). LDL (50 -150 g of protein), in a volume of no more than 100 l, was added to 1 ml of color reagent (0.2 M KH 2 PO 4 , 0.12 M KI, 0.15 mM NaN 3 , 2 g of Triton X-100/liter, 0.1 g of benzalkonium chloride/liter, 10 M ammonium molybdate, 20 M BHT, 25 M EDTA, pH 6.2) and incubated in the dark for 30 min at room temperature; light absorbance at 365 nm was then measured and lipid peroxides were quantified by comparison with a H 2 O 2 standard curve.…”
Section: Methodsmentioning
confidence: 99%
“…The extent of LDL modification was assessed by electrophoretic mobility in 1% agarose. Lipid peroxide levels in oxidized LDL were measured by quantifying the oxidation of iodide to iodine (I 3 ), as described (28). Thiobarbituric acid-reactive substances in preparations of cell-modified LDL were measured as described (29).…”
Section: Methodsmentioning
confidence: 99%
“…The tri-iodide method of El-Saadani et al [60], modified slightly as described previously [56], was used to determine lipid hydroperoxides in oxidised LDL (100 µg protein/ml). This concentration of oxidised LDL was used, rather than 50 µg protein/ml, because the lipid hydroperoxide assay is less sensitive than the conjugated diene assay.…”
Section: Lipid Hydroperoxide Assaymentioning