2015
DOI: 10.1016/j.egypro.2015.12.168
|View full text |Cite
|
Sign up to set email alerts
|

Cooling Systems in Data Centers: State of Art and Emerging Technologies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
43
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 148 publications
(44 citation statements)
references
References 23 publications
0
43
0
1
Order By: Relevance
“…Air has a relatively low heat capacity compared to liquids (water or organic liquids), and is expected to be inadequate for cooling new servers. Other drivers of liquid cooling systems are the reduced cost associated with energy and space savings, and the potential of exploiting the outlet temperature of the liquid coolant to increase the reuse of waste heat (Ebrahimi et al 2014;Capozzoli and Primiceri 2015). Liquid cooling systems may have many different configurations, and several new concepts are being developed (e.g.…”
Section: Ancillary Equipment Efficiencymentioning
confidence: 99%
“…Air has a relatively low heat capacity compared to liquids (water or organic liquids), and is expected to be inadequate for cooling new servers. Other drivers of liquid cooling systems are the reduced cost associated with energy and space savings, and the potential of exploiting the outlet temperature of the liquid coolant to increase the reuse of waste heat (Ebrahimi et al 2014;Capozzoli and Primiceri 2015). Liquid cooling systems may have many different configurations, and several new concepts are being developed (e.g.…”
Section: Ancillary Equipment Efficiencymentioning
confidence: 99%
“…The aim of this communication is to show that model-free control might provide also a most efficient control tool with respect to air conditioning. Remark 1: 1) HVAC, i.e., heating, ventilation, and air conditioning, which is defined by Wikipedia as "the technology of indoor and vehicular environmental comfort" (see, e.g., [29]), plays therefore a key rôle (see, e.g., [11], [28]). The corresponding numbers of publications and patents are increasing rapidly.…”
Section: Introductionmentioning
confidence: 99%
“…The performance of these systems is directly related to the temperature; therefore, it is a crucial issue to maintain the components at acceptable temperature levels. Microchannel heat exchangers have been proven to have relatively higher heat dissipation capabilities than conventional heat removal devices because of their higher heat transfer surface area to fluid volume ratio and have been widely used for electronics cooling in order to maintain the temperatures at an acceptable level. For example, to avoid permanent damage to a laptop CPU, its temperature should not exceed 80 °C to 90 °C .…”
Section: Introductionmentioning
confidence: 99%