2018
DOI: 10.1016/j.expthermflusci.2018.04.011
|View full text |Cite
|
Sign up to set email alerts
|

Convective condensation in three enhanced tubes with different surface modifications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 25 publications
(6 citation statements)
references
References 29 publications
0
5
0
Order By: Relevance
“…A detailed description of the test apparatus with an uncertainty analysis is provided in Li et al [9] and Wu et al [19]. Figure 1a shows the test apparatus made up of a refrigeration circuit and cooling water circuit.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…A detailed description of the test apparatus with an uncertainty analysis is provided in Li et al [9] and Wu et al [19]. Figure 1a shows the test apparatus made up of a refrigeration circuit and cooling water circuit.…”
Section: Methodsmentioning
confidence: 99%
“…Li et al [8] studied tube-side condensation and evaporation characteristics of structured 3D enhanced tubes. A similar experimental investigation has been performed by Li et al [9] in order to evaluate the condensation of novel EHT enhanced tubes. Their results indicate the 1EHT tube exhibited the highest performance factors.…”
Section: Introductionmentioning
confidence: 95%
See 1 more Smart Citation
“…The heat input of the test section varied with the temperature of the thermostat bath and the water flow rates; in order to achieve the desired vapor quality, the refrigerant was heated or cooled in the test section. Additional details of the test apparatus can be obtained from Li et al [21]. Figure 2b illustrates the test section employed in this work; the test section was a double-pipe heat exchanger with an effective heat length of 2 m. In this study, tubes with an inner diameter of 25 mm and 26 mm were employed as the outer tube in order to investigate the effect of annulus width; the tested tubes were used as the inner tube of the heat exchanger.…”
Section: Test Conditionsmentioning
confidence: 99%
“…Research also revealed that the simultaneous drop-wise and film-wise condensations had a higher heat transfer coefficient compared to the single drop-wise or film-wise mode. Li et al (2018a) investigated the performance of different enhanced surfaces for the in-tube convective condensation of R410a.…”
Section: Optimisation Of Operating Conditionsmentioning
confidence: 99%