2016 4th International Conference on Control Engineering &Amp; Information Technology (CEIT) 2016
DOI: 10.1109/ceit.2016.7929116
|View full text |Cite
|
Sign up to set email alerts
|

Control of single-phase grid connected photovoltaic inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0
12

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(18 citation statements)
references
References 14 publications
0
6
0
12
Order By: Relevance
“…In this paper, u ck (n) is collectively referred to as the kth cosine wave. M k is the kth cosine wave amplitude; δ k is the initial phase of the kth cosine wave; T is the sampling time interval; ω is the fundamental angular frequency; Θ is the value set of k. Considering the main low-order harmonics of the actual three-phase grid-connected inverter are 5 and 7 times in practice (Bourguiba et al, 2016), and it is also necessary to control the fundamental wave, the Θ of QSE is set as {1,5,7}.…”
Section: Quadrature Sinewave Extractor Principle Orthogonal Sine Wave...mentioning
confidence: 99%
See 2 more Smart Citations
“…In this paper, u ck (n) is collectively referred to as the kth cosine wave. M k is the kth cosine wave amplitude; δ k is the initial phase of the kth cosine wave; T is the sampling time interval; ω is the fundamental angular frequency; Θ is the value set of k. Considering the main low-order harmonics of the actual three-phase grid-connected inverter are 5 and 7 times in practice (Bourguiba et al, 2016), and it is also necessary to control the fundamental wave, the Θ of QSE is set as {1,5,7}.…”
Section: Quadrature Sinewave Extractor Principle Orthogonal Sine Wave...mentioning
confidence: 99%
“…The current closed-loop controller is an important factor affecting output current harmonics' performance (Cárdenas et al, 2012;Tuan and Santoso, 2016). There are many effective current closed-loop control algorithms for suppressing current harmonics, and the main difference between them is the harmonic extraction method (Castilla et al, 2013;Kulkarni and John, 2013;Zhao et al, 2013;Bourguiba et al, 2016;Wang et al, 2016;Qian et al, 2017;Zhaoyang et al, 2017;Busarello et al, 2018;Hu et al, 2018;McDonald and Li, 2018;Chen et al, 2019;Choi and Sarlioglu, 2019;Fei et al, 2019;Song et al, 2020).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In [7], a proportional-integral (PI) controller is used, but the general problems of this controller include its poor performance, the existence of a steady-state error in load changing, the presence of disturbances, and the failure to follow the sinusoidal reference. The proportional-resonance (PR) controller is provided in [8], [9] for single-phase and three-phase inverters. Although this controller performs better than PI, it has problems such as the need for fine-tuning and high frequency sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…Different control techniques have been adopted to the intermediate DC/DC buck converter interfaces the PV source and the DC-AC inverter. The control of single-phase current source inverter-based grid tie photovoltaic (PV) system has been addressed in [13]. A current control technique for a single-phase grid connected DC/AC inverter which is used in Photovoltaic power conditioning system has been presented in [14].…”
Section: Introductionmentioning