2012
DOI: 10.1109/tie.2011.2165454
|View full text |Cite
|
Sign up to set email alerts
|

Control Design and Implementation for High Performance Shunt Active Filters in Aircraft Power Grids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(7 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…Harmonic filters can suppress harmonic distortion in any reticulation network [22][23][24][25]. A compensator needs to be specified for fluctuating modular plant loading conditions, which is then capable of maintaining the harmonic distortion levels well within the prescribed limits [26][27][28][29]. An economical solution is required in which the capital investment cost related to PFC is recoverable in short time because of lower procurement cost of reactive power [27,30].…”
Section: Problem Formulationmentioning
confidence: 99%
“…Harmonic filters can suppress harmonic distortion in any reticulation network [22][23][24][25]. A compensator needs to be specified for fluctuating modular plant loading conditions, which is then capable of maintaining the harmonic distortion levels well within the prescribed limits [26][27][28][29]. An economical solution is required in which the capital investment cost related to PFC is recoverable in short time because of lower procurement cost of reactive power [27,30].…”
Section: Problem Formulationmentioning
confidence: 99%
“…Hence, many publications [48-56, 60-74, 80-81, 129] have been reviewed on three-phase power quality conditioners suitable for railway traction with many control strategies. In the three-phase power quality conditioners, active filters can be connected in series, shunt [48][49][50][51][52][53][54][55][56][57], combination of series and shunt called unique power quality conditioners [80][81] and passive filters combined with active filters [60][61][62][63][64][65][66][67][68][69][70][71][72][73][74]129] are being used.…”
Section: State Of the Artmentioning
confidence: 99%
“…Also, other publications on three-phase quality conditioners in series configuration [56], shunt [48][49][50][51][52][53][54][55][56][57] and combination of both [60 -74, 129] have been surveyed. Three single-phase converters based on a chain circuit inverters [128] are connected to the power system through isolation transformer, where two phases are connected to two feeders of traction sub-station and the third phase is connected to the ground.…”
Section: Three Phase -Three Wire Power Quality Conditionersmentioning
confidence: 99%
“…The cascaded structure electrical converter could be a worth powerful answer [11] and it reduces harmonics within the system [4], [10]. The UPQC affords higher traits than as compared to individual assortment and shunt energetic strength filters [6], [7], [8], [9]. To operation of the planned UPQC became confirmed via simulation with MATLAB/ Simulink software system program.…”
Section: Introductionmentioning
confidence: 99%