Contrast-Enhanced color doppler US in malignant portal vein thrombosis

Abstract: Contrast-enhanced Doppler US is a reliable diagnostic tool for assessing malignant portal vein thrombosis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
30
0
1

Year Published

2001
2001
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(34 citation statements)
references
References 12 publications
2
30
0
1
Order By: Relevance
“…Its sensitivity proved to be significantly higher than that of triphasic spiral CT for both the detection and characterization of portal vein thrombosis, and in the latter setting, it was also significantly more sensitive than cDUS, confirming previous reports [18][19][20][21].…”
Section: Discussionsupporting
confidence: 86%
See 2 more Smart Citations
“…Its sensitivity proved to be significantly higher than that of triphasic spiral CT for both the detection and characterization of portal vein thrombosis, and in the latter setting, it was also significantly more sensitive than cDUS, confirming previous reports [18][19][20][21].…”
Section: Discussionsupporting
confidence: 86%
“…Arterial neovascularization within a neoplastic thrombus results in arterial enhancement, which, on real-time imaging, can be easily distinguished from venous enhancement by its intermittent pulsation. Confirmation of the signal's arterial nature with Doppler spectral analysis has been shown to indicate malignancy with very high specificity [18][19][20][21]. False positives caused by the incorrect placement of the Doppler sample volume at a point in which the hepatic artery crosses over the portal vein has been reported for CEUS [20] and for cDUS [6].…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…CEUS has the potential of playing an important role in this respect. 26 In our study, the image analysis was performed in consensus instead independently between readers, which might lead to bias even though this method is widely used. Further studies are needed to assess the differences in characterization among different observers with an aim to evaluate the reliability and acceptance of CEUS.…”
Section: Discussionmentioning
confidence: 99%
“…From our own experience using Levovist, the diagnosis can be more confident, both in harmonic and colour Doppler modes after contrast injection. The detection of flow within the thrombus may also be improved [26].…”
Section: Liver Vesselsmentioning