2010
DOI: 10.1378/chest.09-2850
|View full text |Cite
|
Sign up to set email alerts
|

Continuous Positive Airway Pressure Effects on Regional Lung Aeration in Patients With COPD

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
28
1
2

Year Published

2012
2012
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(35 citation statements)
references
References 34 publications
4
28
1
2
Order By: Relevance
“…The calibration is carried out within three months taking exams, as specified by the manufacturer (Toshiba, 1997). Moreover, a tomographic cut with a water phantom with a known density is performed for analysis and parameter control (Holanda et al, 2010). The images are quantified in 16 bits and stored in a DICOM format (Digital Imaging and Communications in Medicine).…”
Section: The Medical Image Acquisition and Lung Segmentationmentioning
confidence: 99%
See 2 more Smart Citations
“…The calibration is carried out within three months taking exams, as specified by the manufacturer (Toshiba, 1997). Moreover, a tomographic cut with a water phantom with a known density is performed for analysis and parameter control (Holanda et al, 2010). The images are quantified in 16 bits and stored in a DICOM format (Digital Imaging and Communications in Medicine).…”
Section: The Medical Image Acquisition and Lung Segmentationmentioning
confidence: 99%
“…The data set comprises an image cluster obtained in collaboration with the Walter Cantídio Hospital of the Federal University of Ceará, submitted to an earlier study (Holanda et al, 2010;Winkeler, 2006). This study was approved and evaluated by the UFC Research Ethics Committee -COMEPE, (Protocol nº 35/06) and complied with the demands of Resolution nº 196/96 of the National Health Council, concerning research in human beings.…”
Section: The Medical Image Acquisition and Lung Segmentationmentioning
confidence: 99%
See 1 more Smart Citation
“…For instance, NIV reduces total lung capacity by 10% in stable hypercapnic COPD, possibly from increased cross-sectional areas of the airways, decreased airway resistance, and increased expiratory time, which may facilitate the emptying of diseased lung units. 24,25 In contrast, other studies have shown that CPAP only temporarily decreases hyperinflation in COPD. 26 Similarly, high-resolution computed tomographic studies show that although low CPAP (5 cm H 2 O) may cause regional deflation in some subjects, higher CPAP (10 -15 cm H 2 O) may promote overinflation of already hyperinflated zones.…”
Section: Discussionmentioning
confidence: 92%
“…26 Similarly, high-resolution computed tomographic studies show that although low CPAP (5 cm H 2 O) may cause regional deflation in some subjects, higher CPAP (10 -15 cm H 2 O) may promote overinflation of already hyperinflated zones. 25 One study showed that generally low CPAP (4 -11 cm H 2 O) in COPD can be individualized to the level best associated with an improvement in inspiratory capacity particularly in subjects with an emphysema phenotype rather than a chronic bronchitis phenotype of COPD. 27 Although we did not classify our subjects based on the COPD phenotype, our study does suggest that subjects with increased weight (more commonly associated with the chronic bronchitis phenotype) have better adherence (see Table 1), whereas those with lower diffusion capacity (more commonly associated with the emphysema phenotype) have a flatter diaphragm and reduced later adherence (see Table 2).…”
Section: Discussionmentioning
confidence: 99%