1945
DOI: 10.1021/i560141a003
|View full text |Cite
|
Sign up to set email alerts
|

Continuous Determination of Ammonia Activity in Ammoniacal Solutions

Abstract: The iodine pentoxide reagent must completely oxidize low concentrations of carbon monoxide at comparatively low temperatures in the presence of about 75% hydrogen and in addition must maintain its activity for a long period. The following procedure, using reagent-grade chemicals, gives a reagent that has an active life of 30 to 40 days.Seventy grams of calcined, crushed insulating brick (Armstrong A-25; -9+14 mesh) are added to a solution containing 100 grams of iodine pentoxide and 4 grams of vanadium pentoxi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0

Year Published

1945
1945
1997
1997

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 10 publications
0
6
0
Order By: Relevance
“…To remove from the nitrogen all traces of oxygen, whether present as such or in the form of water or carbon dioxide, a purification system was used consisting of: (1) a suitable length of a.Vycor or Pyrcx glass microcombustion tube containing a 10-cm. section of copper grit (40-to 60-mesh) or ribbon mounted vertically to avoid channeling of the filling and maintained at about 500°C.…”
Section: Apparatusmentioning
confidence: 99%
See 3 more Smart Citations
“…To remove from the nitrogen all traces of oxygen, whether present as such or in the form of water or carbon dioxide, a purification system was used consisting of: (1) a suitable length of a.Vycor or Pyrcx glass microcombustion tube containing a 10-cm. section of copper grit (40-to 60-mesh) or ribbon mounted vertically to avoid channeling of the filling and maintained at about 500°C.…”
Section: Apparatusmentioning
confidence: 99%
“…Iodine Pentoxide-Vanadium Pentoxide. This oxidation tube filling is prepared as described by Brown and Felger (1), except that 20to 30-mesh Armstrong A-25 insulating brick is used instead of 9-to 14-mesh. With this filling, a temperature of 110-111°C.…”
Section: Apparatusmentioning
confidence: 99%
See 2 more Smart Citations
“…The complete analyzer is shown in Figure 1. The pressure stabilizer, P (6), gives a constant operating pressure and is adjusted so that the rate of leakage around the piston reduces the time Sag in the sample line to 15 seconds or less. Valve V and flowmeter F are used to regulate the rate of gas flow through the train.…”
Section: Operating Principlementioning