2018
DOI: 10.1016/j.chroma.2018.03.031
|View full text |Cite
|
Sign up to set email alerts
|

Construction of chiral ligand exchange capillary electrochromatography for d , l -amino acids enantioseparation and its application in glutaminase kinetics study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 30 publications
0
11
0
Order By: Relevance
“…In recent years, there were many novel homo‐polymers or copolymers synthesized in order to meet the needs for the separation of different analytes . Liu and co‐workers reported an example of partially filled PLOT capillary column with immobilized pH gradient (PLOT‐IPG) for OT‐CEC analysis of amino acids and proteins.…”
Section: Open‐tubular Capillary Electrochromatographymentioning
confidence: 99%
See 1 more Smart Citation
“…In recent years, there were many novel homo‐polymers or copolymers synthesized in order to meet the needs for the separation of different analytes . Liu and co‐workers reported an example of partially filled PLOT capillary column with immobilized pH gradient (PLOT‐IPG) for OT‐CEC analysis of amino acids and proteins.…”
Section: Open‐tubular Capillary Electrochromatographymentioning
confidence: 99%
“…Zhao et al. developed a block copolymer poly(maleic anhydridestyrene‐methacryloyl‐l‐arginine methyl ester) coated capillary. The prepared OT‐column could be used for the enantiomer separation of d , l ‐amino acids on the base of synergistic ligands effect of the immobilized polymethylacrylic acid in the coating and free l ‐arginine in buffer solution.…”
Section: Open‐tubular Capillary Electrochromatographymentioning
confidence: 99%
“…Qi’s group [41] developed a chiral ligand exchange stationary phase poly(maleic anhydride-styrene-methacryloyl- l -arginine methyl ester) for the enantioseparation of d , l -amino acids. The chiral stationary phase showed excellent enantioseparation performance.…”
Section: Open-tubular Columnmentioning
confidence: 99%
“…At present, chromatography and electrophoresis (CE) methods are mostly employed for the detection of SA residues, about 75% of the total [4]. Capillary electrochromatography (CEC) is considered to combine the advantages of the high separation efficiency of CE and the selectivity supplied by liquid chromatography [5,6]. It is important to realize that the CEC system operates with small sample quantities (nanolitre amounts) and sample vials used for the introduction of the sample only require microlitre quantities (typically greater than or equal to 50 µl), which is quite attractive for precious biological samples [7].…”
Section: Introductionmentioning
confidence: 99%