2011
DOI: 10.1117/12.894089
|View full text |Cite
|
Sign up to set email alerts
|

Construction of a high power OPO laser system for differential absorption LIDAR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…The results of experimental measurements of the CH4 concentration distribution along a 800 m sounding path with the OPO lidar system are shown in Figure 10. The background concentration of methane was calculated using the equation shown in Equation (2). The path averaged methane concentration of about 2.085 ppm over the path length of 800 m was retrieved.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The results of experimental measurements of the CH4 concentration distribution along a 800 m sounding path with the OPO lidar system are shown in Figure 10. The background concentration of methane was calculated using the equation shown in Equation (2). The path averaged methane concentration of about 2.085 ppm over the path length of 800 m was retrieved.…”
Section: Discussionmentioning
confidence: 99%
“…The experimental results show applicability of the IR OPO lidar system to study the distribution of methane concentration (~2.085 ppm) at 800 m atmospheric path with a spatial resolution of 100 m in the mid-IR. The error level of The background concentration of methane was calculated using the equation shown in Equation (2). The path averaged methane concentration of about 2.085 ppm over the path length of 800 m was retrieved.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Especially, differential absorption lidars (DIALs) developed rapidly these years [9,10]. For example, spaceborne integrated path differential absorption (IPDA) lidar technique is an effective means for the global column-averaged CO 2 concentration measurement with high precision and low bias.…”
Section: Introductionmentioning
confidence: 99%
“…For this kind of application several solid state laser approaches are being investigated, which are mainly based on injection seeded Ho or Ho:Tm laser oscillators at 2 µm for CO 2 concentration measurement [5,6], or based on injection seeded optical parametric devices [7][8][9][10][11]. Optical parametric devices are well suited since they provide wide potential tuning ranges and sufficient output energy especially in the mid-IR where laser options are scarce.…”
Section: Context and Elements Of Bibliographymentioning
confidence: 99%