Construction and commissioning of a 215-m-long beamline at SPring-8

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
72
0

Year Published

2003
2003
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 124 publications
(72 citation statements)
references
References 6 publications
0
72
0
Order By: Relevance
“…28) A bending magnet was employed as an X-ray source, and the radiation was monochromatized with Si double crystal monochromator (36.8 m from the X-ray source point). The beam divergences of 1.5 mrad in the horizontal direction and 0.06 m rad in vertical direction provide a high coherent Xray beam at the sample position.…”
Section: Setup Of Observation Apparatusmentioning
confidence: 99%
See 1 more Smart Citation
“…28) A bending magnet was employed as an X-ray source, and the radiation was monochromatized with Si double crystal monochromator (36.8 m from the X-ray source point). The beam divergences of 1.5 mrad in the horizontal direction and 0.06 m rad in vertical direction provide a high coherent Xray beam at the sample position.…”
Section: Setup Of Observation Apparatusmentioning
confidence: 99%
“…Both an absorption contrast due to the difference in absorption and a phase contrast due to the difference in density, which enhances phase boundaries in a specimen, are obtained in the X-ray transmitted images. 28,29) Figure 3(a) shows a setup for observing solidification of pure Fe. An ion chamber for measuring intensity of incident X-ray beam, vacuum chamber in which a specimen with a heating system is set, and an X-ray detector are placed along X-ray beam stream.…”
Section: Setup Of Observation Apparatusmentioning
confidence: 99%
“…The consistent overestimation of PS Area with respect to that obtained experimentally, which we denote as large distance error, could be due to a number of possible effects. While partial coherence (penumbral blurring) was deemed negligible based on the source size given by Goto et al [35], the effects on speckle contrast may be larger than expected. Our group has also found discrepancies between simulated lung speckle contrast using the projection approximation and the more rigorous multi-slice diffraction method, which may also account for the differences.…”
Section: 90±001mentioning
confidence: 87%
“…The imaging hutch was located in the Biomedical Imaging Centre, 211 meters from the source, 31 and the imaging layout was as described previously, 10 Monochromatic 25 keV (λ=0.5Å) X-rays were selected using a Si(111) double-crystal monochromator to provide maximum flux at this energy, 32 A propagation (sample to detector) distance of ~2 m was chosen to produce optimal phase contrast for airway imaging. X-rays were converted to visible light using a P43 (Gd 2 O 2 S:Tb) scintillator and images were captured using a CCD detector (C9300-124F21, Hamamatsu Photonics) coupled to the scintillator using a fiber optic taper.…”
Section: Imaging Setupmentioning
confidence: 99%