2014
DOI: 10.1002/elan.201300619
|View full text |Cite
|
Sign up to set email alerts
|

Construction and Application of an Electrochemical Sensor for Simultaneous Determination of Cd(II), Cu(II) and Hg(II) in Water and Foodstuff Samples

Abstract: By incorporation of synthesized magnetite nanoparticles (Fe3O4 NPs) coated with a new Schiff base into carbon paste electrode, a novel modified electrode was constructed for simultaneous determination of ultra trace amounts of Cd(II), Cu(II) and Hg(II). The complexation reaction of Schiff base with metal ions was studied spectrophotometrically. Under optimal conditions a detection limit of 0.20, 0.90 and 1.00 ng mL−1 for Cd(II), Cu(II) and Hg(II), respectively, was obtained. We take the advantages of the propo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(6 citation statements)
references
References 50 publications
0
5
0
Order By: Relevance
“…As shown in Figure 1 a, large RGO/CMC nanosheets are observed in the TEM image without agglomeration. FT-IR spectrum of RGO/CMC ( Figure 1 b) indicates that GO has been effectively reduced as the absorption intensity of the hydroxyl (3428 cm −1 ) and epoxy (1047 cm −1 ) were evidently decreased [ 21 ]. Furthermore, the new absorption peak appearing at 2925 cm −1 ascribed to the methyl and methylene of CMC, confirms the successful modification of CMC on the surface of RGO [ 22 , 23 ].…”
Section: Resultsmentioning
confidence: 99%
“…As shown in Figure 1 a, large RGO/CMC nanosheets are observed in the TEM image without agglomeration. FT-IR spectrum of RGO/CMC ( Figure 1 b) indicates that GO has been effectively reduced as the absorption intensity of the hydroxyl (3428 cm −1 ) and epoxy (1047 cm −1 ) were evidently decreased [ 21 ]. Furthermore, the new absorption peak appearing at 2925 cm −1 ascribed to the methyl and methylene of CMC, confirms the successful modification of CMC on the surface of RGO [ 22 , 23 ].…”
Section: Resultsmentioning
confidence: 99%
“…The increase in the peak current with time is due to the accumulation of metal ions onto the electrode interface [44]. Then, the decrease in the peak current might be due to the surface saturation on the electrode [45,46]. Hence, a pre-concentration time of 5 min has been optimized and used in all further studies.…”
Section: Effect Of Preconcentration Timementioning
confidence: 99%
“…Heavy metal may exist in food either naturally or as a consequence of anthropic sources. They have destructive effect to human health even at low concentration when ingested over a long period of time [3,4]. Thus, it is important to ensure that such heavy metal should be kept below the maximum limit that is allowed by WHO in milligrams per milliliter range [5,6].…”
Section: Introductionmentioning
confidence: 99%