2019
DOI: 10.1007/s10334-019-00802-x
|View full text |Cite
|
Sign up to set email alerts
|

Consensus-based technical recommendations for clinical translation of renal BOLD MRI

Abstract: Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplement… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
66
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 78 publications
(73 citation statements)
references
References 51 publications
(74 reference statements)
2
66
0
Order By: Relevance
“…This is solely a limiting case in small animals, and as such, focal differentiation is possible in humans. All MRI methods can be applied in humans [ 31 , 32 , 33 , 34 , 35 , 36 , 37 ]. However, the use of gadolinium contrast agents is contradicted in severe CKD, and as such, alternative methods would likely be used to determine the hemodynamic nature of kidneys in humans [ 38 ].…”
Section: Discussionmentioning
confidence: 99%
“…This is solely a limiting case in small animals, and as such, focal differentiation is possible in humans. All MRI methods can be applied in humans [ 31 , 32 , 33 , 34 , 35 , 36 , 37 ]. However, the use of gadolinium contrast agents is contradicted in severe CKD, and as such, alternative methods would likely be used to determine the hemodynamic nature of kidneys in humans [ 38 ].…”
Section: Discussionmentioning
confidence: 99%
“…with their own strengths and weaknesses (30). International effort is now being made to standardize the BOLD-MRI protocols, including patient preparation, image acquisition, and analysis (30,31). Urine oximetry is another method that has a potential to be used in clinical settings.…”
Section: Methods To Detect Hypoxia In the Kidneymentioning
confidence: 99%
“…MR axial images were acquired during breath-hold (≤ 20 s). BOLD-MRI mostly followed PARENCHIMA guidelines, and the MRI parameters used in this study as well as PARENCHIMA's recommendations are summarized in the Supplementary Table 1 16,23 .…”
Section: Methodsmentioning
confidence: 99%