1997
DOI: 10.1007/s002160050240
|View full text |Cite
|
Sign up to set email alerts
|

Congener-specific method for the determination of ortho and non-ortho polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans in foods by carbon-column fractionation and gas chromatography-isotope dilution mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0
1

Year Published

2000
2000
2016
2016

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 0 publications
0
10
0
1
Order By: Relevance
“…The use of a carbon column has previously been demonstrated to be suitable for the separation of ortho-substituted PCB, non-ortho substituted PCB, and PCDD/F according to their structure-affinity relationship [20]. In this study, however, only the cPCB were actually isolated via the carbon column, because their coplanar 376 properties enable them to be trapped between planar carbon layers until their displacement by use of the structurally related toluene solvent [21].…”
Section: Correlation Of the Retention Of Pcb With Their Electronic Anmentioning
confidence: 98%
“…The use of a carbon column has previously been demonstrated to be suitable for the separation of ortho-substituted PCB, non-ortho substituted PCB, and PCDD/F according to their structure-affinity relationship [20]. In this study, however, only the cPCB were actually isolated via the carbon column, because their coplanar 376 properties enable them to be trapped between planar carbon layers until their displacement by use of the structurally related toluene solvent [21].…”
Section: Correlation Of the Retention Of Pcb With Their Electronic Anmentioning
confidence: 98%
“…Extraction and cleanup were performed by matrix solid phase dispersion following a semiautomatic procedure [17] previously described in detail [16]. This comprises a low‐pressure liquid chromatography system in which the three non‐ ortho (77, 126, and 169) PCBs (Fraction A) were separated from the bulk of the PCBs and lipids (Fraction B).…”
Section: Methodsmentioning
confidence: 99%
“…Gas chromatographic separation of the nine atropisomeric PCB congeners in their atropisomers was carried out with the Thermo Quest Finnigan HRGC/ITD system described previously, using a Chirasil‐Dex column (25 m × 0.25‐mm i.d., 0.2‐μm film thickness, Alltech, Deerfield, IL, USA) [17].…”
Section: Methodsmentioning
confidence: 99%
“…Silica and alumina or Florisil are used to fractionate or remove as many non-dioxin-like compounds as possible prior to the carbon cleanup stage. Poole et al (1990), Krokos et al (1997), Kloskowski et al (2007), Fernandez et al (2004), Djien Liem, (1999), Sandra, Frank and Vanhoenecker (2008), Santos and Galceran (2002) have reviewed a variety of sample preparation techniques for gas chromatographic analysis.…”
Section: Extract Cleanupmentioning
confidence: 99%