Conceptual design of a wearable radiation detector alarm system: a review of the literature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 56 publications
0
4
0
Order By: Relevance
“…Bi, I), BiSI is a potential candidate for this application [4]. Ionising radiation detection is essential in many fields, from nuclear medicine [5,6], to homeland security [7][8][9]. While there are several commercial detectors which serve these purposes, the need to minimize the radiation exposure is always present [10].…”
Section: Introductionmentioning
confidence: 99%
“…Bi, I), BiSI is a potential candidate for this application [4]. Ionising radiation detection is essential in many fields, from nuclear medicine [5,6], to homeland security [7][8][9]. While there are several commercial detectors which serve these purposes, the need to minimize the radiation exposure is always present [10].…”
Section: Introductionmentioning
confidence: 99%
“…This, at least, is the result if the component unisensory signals are presented from the same spatial location (or at least from the same direction). Cucially, though, multisensory warning signals lose their attentional capture advantage if the component unisensory cues are presented from different spatial locations/directions (Ho, Santangelo, & Spence, 2009), as tends to be the case in many real world multisensory warning systems.…”
Section: Multisensory Warning Signal Design -Insights From Cognitive mentioning
confidence: 99%
“…The logic behind multimodal signals for notifying operators is based on the fact that operators frequently process a variety of data streams to ascertain the existence of a problem. Alarm respondents frequently rely on the presence of redundant or additional information to confirm signal validity (Bliss, 2003) and first responders seem to prefer alarms that engage multiple modalities (Herring & Hallbeck, 2010). As noted by Herring and Hallbeck, highly consequential task environments such as radiation detection benefit greatly from multimodal alarm presentation but also suffer greatly from a lack of signal reliability.…”
Section: Multisensory Warning Signal Design -Insights From Cognitive mentioning
confidence: 99%
See 1 more Smart Citation