1969
DOI: 10.1007/bf01540924
|View full text |Cite
|
Sign up to set email alerts
|

Computer calculation of two target trajectory with “centre of arc-target” stereotaxic equipment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

1974
1974
2009
2009

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…At the meeting of the World Society for Stereotactic and Functional Neurosurgery in 1973, six papers described the use of computers in stereotactic surgery [15]. As early as 1969, Peluso and Gybels [16,17] used a computer to determine a stereotactic target [16] and to define two targets along a single trajectory [17], probably the first intraoperative use of a computer for surgical guidance. It was not long afterward that Birg and Mundinger [18] followed.…”
Section: Computers In Neurosurgerymentioning
confidence: 99%
“…At the meeting of the World Society for Stereotactic and Functional Neurosurgery in 1973, six papers described the use of computers in stereotactic surgery [15]. As early as 1969, Peluso and Gybels [16,17] used a computer to determine a stereotactic target [16] and to define two targets along a single trajectory [17], probably the first intraoperative use of a computer for surgical guidance. It was not long afterward that Birg and Mundinger [18] followed.…”
Section: Computers In Neurosurgerymentioning
confidence: 99%
“…In our previous papers [1][2][3][4] we have developed the general principles and calculations of three coordinates of the electrode point during penetra tion for each penetration depth with respect to a chosen reference system. An example of such calculations is shown in figure IB.…”
Section: Graphic Representation O F Electrode Point During Penetrationmentioning
confidence: 99%
“…At that occasion we gave a review of the work of our group, most of which has been published in previous years [1][2][3][4]. In this paper we will only be concerned with the graphic representation of the electrode point during penetration of the brain, and with calculations for two-stage stereotaxic surgery, procedures which we have not published previously.…”
mentioning
confidence: 99%
“…The reason is even stronger considering that as a consequence of the small structures of the hypothalamus, midbrain and upper brain stem, the tolerances must not be more than a few tenths of a millimeter in order to avoid great risks [4,5,7,9,11,25,26].…”
mentioning
confidence: 99%