2012
DOI: 10.5862/mce.29.9
|View full text |Cite
|
Sign up to set email alerts
|

Computational justification for engineering measures preventing the ice dams formation on the pitched roofs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 1 publication
(1 reference statement)
0
6
0
Order By: Relevance
“…Technical and economic indicators of application of the heat supply system based on heat pump depend on the cost of electricity and capital investments for the heat supply system. Further, the cost of electricity decreases with a decrease in temperature of the heat pump condenser and with an increase in temperature of evaporator, but this increases capital costs in the heating system, as the area of heat exchangers, radiators and heaters increases [11].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Technical and economic indicators of application of the heat supply system based on heat pump depend on the cost of electricity and capital investments for the heat supply system. Further, the cost of electricity decreases with a decrease in temperature of the heat pump condenser and with an increase in temperature of evaporator, but this increases capital costs in the heating system, as the area of heat exchangers, radiators and heaters increases [11].…”
Section: Methodsmentioning
confidence: 99%
“…Capital investments of the enterprise comprise the cost of: construction and installation work in the construction of buildings and structures; purchase, installation and commissioning of machinery and equipment; design and survey work; training and retraining of personnel, etc [19,11]. КВ hps = (С hp + С мр + С heat syst. )…”
Section: Investments In the Heat Pump Stationmentioning
confidence: 99%
“…A research of A. Gorshkov, N. Vatin, P. Rymkevich, O. Kudrevich contains a developed mathematical mode for evaluating the discounted payback period which could be widely used for construction evaluation purposes [8].…”
Section: Introductionmentioning
confidence: 99%
“…For other types of energy-saving measures, annual savings can be obtained based on the analysis and evaluation of energy-saving design solutions [8][9][10][11][12]. The area where it is possible to quickly reduce the amount of fuel consumed and as a result, energy consumption and emissions into the atmosphere -it's housing, which according to various estimates consumes 30 to 40% of all energy [13][14][15]. To do this, it is sufficient to increase the regulatory requirements for the level of thermal insulation [14], to improve the degree of building automation when adjusting the parameters of the heat transfer fluid at the building entrance, to install exhaust heat heat recovery systems [16] and more efficient heating systems.…”
Section: Introductionmentioning
confidence: 99%