2017
DOI: 10.1109/tpwrd.2016.2555856
|View full text |Cite
|
Sign up to set email alerts
|

Computation of Peak Lightning-Induced Voltages Due to the Typical First and Subsequent Strokes Considering High Ground Resistivity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
3
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(4 citation statements)
references
References 35 publications
0
3
0
1
Order By: Relevance
“…Considering the above, it can be concluded that the location of the line, the category of the receivers, and the design peculiarities of the line are important for the selection of the method of overvoltage protection of power grids. Determining the parameters of the expected atmospheric surges is important in the context of the selection of surge protection devices [11,12]. There are also different methods to coordinate overhead line insulation and surge protection devices [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…Considering the above, it can be concluded that the location of the line, the category of the receivers, and the design peculiarities of the line are important for the selection of the method of overvoltage protection of power grids. Determining the parameters of the expected atmospheric surges is important in the context of the selection of surge protection devices [11,12]. There are also different methods to coordinate overhead line insulation and surge protection devices [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…O presente trabalho visa, com base da teoria proposta por Rusck (1957), estendida por Paulino (1994) e através das equações de pico de tensão induzida apresentadas em Paulino (2019), analisar o impacto do aterramento elétrico no desempenho de linhas de distribuição frente a descargas indiretas. É utilizada como abordagem para estimar a tensão induzida a proposta de Paulino (2019) que, além de ser de simples implementação e atualizada, tem demonstrado boa precisão (para solos com resistividade até 1.000 Ω.m) e excelente desempenho computacional (tempo computacional reduzido) quando comparada com modelos mais robustos como o FDTD Rizk et al (2017).…”
Section: Introdu ç ãOunclassified
“…For the selection of an appropriate insulation level and the design of an effective protection scheme in medium voltage lines, the assessment of lightning flashover rate is unavoidable [6,7]. Because lightning stroke variables are stochastic in nature, peak lightning-induced overvoltage's (LIVs) also vary wildly.…”
Section: Introductionmentioning
confidence: 99%