2022
DOI: 10.1016/j.applthermaleng.2022.118124
|View full text |Cite
|
Sign up to set email alerts
|

Compression effect of metal foam on melting phase change in a shell-and-tube unit

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 63 publications
(4 citation statements)
references
References 62 publications
0
4
0
Order By: Relevance
“…Buonomo et al [36] used Darcy-Fochheimer's law and local thermal equilibrium model to numerically describe the heat transfer between metal foam and PCM. Guo et al [37] attempted to investigate the influences of compression upon melting of paraffin-foam hybrid. Compared with uncompressed foam, observations revealed that compression had a predominated effect on melting, at a reduction rate of 13.9% in melting time.…”
Section: Introductionmentioning
confidence: 99%
“…Buonomo et al [36] used Darcy-Fochheimer's law and local thermal equilibrium model to numerically describe the heat transfer between metal foam and PCM. Guo et al [37] attempted to investigate the influences of compression upon melting of paraffin-foam hybrid. Compared with uncompressed foam, observations revealed that compression had a predominated effect on melting, at a reduction rate of 13.9% in melting time.…”
Section: Introductionmentioning
confidence: 99%
“…Also, they detected that an 84.7% improvement in melting uniformity was achieved by a non-uniform design. Guo et al [52] studied the compression effect of metal foam on melting phase change in a shell-and-tube unit. Yang et al [53] investigated the effect of fin number on the melting phase change in a horizontal finned shell-and-tube thermal energy storage unit, and they found that the melting time can maximally be saved as high as 72.85% by increasing fin number.…”
Section: Introductionmentioning
confidence: 99%
“…Several investigations have been carried out by different researchers to improve the performance of the EC system. The major factors that significantly affect the performance of the EC system are air flow rate, condition of ambient air like dry bulb temperature, humidity, etc., the water flow rate through the cooling pads, thickness, density, and material of cooling pads [ 8 , 9 , 10 , 11 , 12 , 13 ]. The selection of the wet media pad material depends on many factors such as safety, cost, availability, effectiveness, and application [ 14 ].…”
Section: Introductionmentioning
confidence: 99%