2019
DOI: 10.1109/access.2019.2930413
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive Overview of Low Voltage Ride Through Methods of Grid Integrated Wind Generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
90
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 156 publications
(91 citation statements)
references
References 191 publications
0
90
0
1
Order By: Relevance
“…[6]- [9]. The other important issues associated with RE placement, sizing and voltage ride-through in distribution systems reported in [10], [11]. Research work to resolve the issues of power quality associated with WES, SPV, and FC is investigated using simulation studies [12] and hardware approach [13].…”
mentioning
confidence: 99%
“…[6]- [9]. The other important issues associated with RE placement, sizing and voltage ride-through in distribution systems reported in [10], [11]. Research work to resolve the issues of power quality associated with WES, SPV, and FC is investigated using simulation studies [12] and hardware approach [13].…”
mentioning
confidence: 99%
“…The ability of wind turbine based power plants to stay connected to the grid during faults or voltage dips for a specified period is called Low Voltage Ride-Through (LVRT) capability [131]. Several innovative techniques have been reported in the literature to enhance the system ride-through capability, including a wide range of control strategies [82].…”
Section: H Low Voltage Ride-through (Lvrt) Capabilitymentioning
confidence: 99%
“…Substituting the control inputs from (26) and (27) in (24) and (25), we have Figure 4b shows a block representation of the MSC controller based on (28) and (29), which includes the current control and maximum power point tracking (MPPT) control loops. In the current control loop, the current reference i * sd is set equal to zero and i * sq is given by (30).…”
Section: Converter Controller Of Type-4 Pmsg Wind Turbine Generatormentioning
confidence: 99%
“…The reference current is reduced when the DC-link voltage increases, which reduces the machine side power and the DC-link voltage during fault condition. The MSC controller is designed with the de-loading technique in [27] to improve the LVRT operation of the WTG, as shown in Figure 6. The q-axial current reference of the MSC is multiplied with the droop DC-link voltage.…”
Section: Lvrt Control Strategiesmentioning
confidence: 99%