2002
DOI: 10.1021/ac011071z
|View full text |Cite
|
Sign up to set email alerts
|

Composition of Explosives by Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Abstract: Commercial explosives are complex mixtures that contain not only the active explosive agent(s) but also a host of other organic and inorganic compounds. The ultrahigh mass resolving power (m/delta m50% >200,000) and mass accuracy (<1 ppm) of electrospray ionization Fourier transform ion cyclotron resonance (ESI FTICR) mass spectrometry allow for definitive identification of various species in TNT, RDX, and HMX. We are thereby able to correct prior misassignments of the elemental compositions of the most abunda… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
51
0

Year Published

2002
2002
2020
2020

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 61 publications
(53 citation statements)
references
References 32 publications
2
51
0
Order By: Relevance
“…10 The presence of formate could also be due to a trace amount of formic acid left from previous experiments. Even though the system was thoroughly cleaned with acetonitrile, methanol, and water for the current investigation, it is possible that a trace level of formic acid still exists in the system as an impurity.…”
Section: As [M+hcoo]mentioning
confidence: 99%
See 1 more Smart Citation
“…10 The presence of formate could also be due to a trace amount of formic acid left from previous experiments. Even though the system was thoroughly cleaned with acetonitrile, methanol, and water for the current investigation, it is possible that a trace level of formic acid still exists in the system as an impurity.…”
Section: As [M+hcoo]mentioning
confidence: 99%
“…7,10 To improve the signals of the [M+Cl] -ions, chloride ions were often intentionally added. 7 Recently, the addition of HCl to the spray solvent in the DESI analysis of RDX and HMX provided [M+ 35 Cl]…”
Section: As [M+hcoo]mentioning
confidence: 99%
“…The ultrahigh mass accuracy provided by FT-ICR makes it possible to determine the elemental composition of small and large molecules from direct mass measurement [6][7][8][9]. Since the introduction of electrospray ionization (ESI) and matrixassisted laser desorption/ionization (MADLI), the demand for higher mass accuracy has increased with the growing complexity of the samples and of the average mass of the samples.…”
Section: Introductionmentioning
confidence: 99%
“…The ultra-high mass resolution of FT-ICR MS often makes it possible to identify organic molecules based solely on the measured mass to charge (m/z) values. FT-ICR MS has been successfully applied to organic mixtures such as metabolites, 1 vegetable oils, 2 wine, 3 explosives, 4 coal extracts, 5 humic materials, 6,7 and crude oils. 8,9 Broadband FT-ICR MS spectra of these types of organic mixtures are usually very complex, with peaks appearing over a wide dynamic range.…”
Section: Introductionmentioning
confidence: 99%