2019
DOI: 10.1038/s41598-019-48636-w
|View full text |Cite
|
Sign up to set email alerts
|

Complex Susceptibilities and Chiroptical Effects of Collagen Measured with Polarimetric Second-Harmonic Generation Microscopy

Abstract: Nonlinear optical properties of collagen type-I are investigated in thin tissue sections of pig tendon as a research model using a complete polarimetric second-harmonic generation (P-SHG) microscopy technique called double Stokes-Mueller polarimetry (DSMP). Three complex-valued molecular susceptibility tensor component ratios are extracted. A significant retardance is observed between the chiral susceptibility component and the achiral components, while the achiral components appear to be in phase with each ot… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
69
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 41 publications
(71 citation statements)
references
References 62 publications
2
69
0
Order By: Relevance
“…To validate the dual‐ and single‐shot R ‐ratio measurement techniques, DSMP measurements were performed on the muscle sample and the R and C‐ ratios were obtained. Then, using s 0 and s 3 SHG images for RCP and LCP inputs extracted from the DSMP dataset, SHG‐CD and CA CD values were calculated. CA‐values were also calculated separately for right‐ and left‐circularly polarized incident beam (CA R or CA L , respectively).…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…To validate the dual‐ and single‐shot R ‐ratio measurement techniques, DSMP measurements were performed on the muscle sample and the R and C‐ ratios were obtained. Then, using s 0 and s 3 SHG images for RCP and LCP inputs extracted from the DSMP dataset, SHG‐CD and CA CD values were calculated. CA‐values were also calculated separately for right‐ and left‐circularly polarized incident beam (CA R or CA L , respectively).…”
Section: Resultsmentioning
confidence: 99%
“…The SHG‐CD and CA CD values extracted from the DSMP dataset are presented in Figure 3B,C, respectively. The SHG‐CD histogram shows a normal distribution with a mean 0.02 and a standard deviation of 0.16 indicating that most fibers are in the image plane ( α = 0) . Therefore, the sample structure can be described by a C 6 v model .…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations