1974
DOI: 10.1097/00000658-197410000-00006
|View full text |Cite
|
Sign up to set email alerts
|

Complete Left Ventricular Bypass With a Paracorporeal Pump

Abstract: A multidiscipline group was established at The Pennsylvania State University to design and evaluate mechanical circulatory assist devices and the artificial heart. The group has designed a left ventricular to aortic assist system which consists of a sac-type pump, a synchronization unit, a pneumatic power unit, and appropriate monitoring apparatus. The assist system has been evaluated for long-term circulatory assistance in a series of ten calves. The assist pump was placed in the paracorporeal position. The l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

1977
1977
2014
2014

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 20 publications
(6 citation statements)
references
References 6 publications
0
6
0
Order By: Relevance
“…The initial development of ventricular assist devices (VADs) began in the 1970s as a permanent treatment option for end-stage heart failure [1,2]. However, from the mid 1980s, the focus of VAD development shifted to left ventricular support without heart resection, and left ventricular assist devices (LVADs) have since become a viable therapeutic approach as a bridge to cardiac transplantation (BTT) [3,4].…”
Section: Introductionmentioning
confidence: 99%
“…The initial development of ventricular assist devices (VADs) began in the 1970s as a permanent treatment option for end-stage heart failure [1,2]. However, from the mid 1980s, the focus of VAD development shifted to left ventricular support without heart resection, and left ventricular assist devices (LVADs) have since become a viable therapeutic approach as a bridge to cardiac transplantation (BTT) [3,4].…”
Section: Introductionmentioning
confidence: 99%
“…The measurement of flow field velocities in left ventricular assist devices (LVAD) facilitates the identification of regions potentially causing thrombosis, clot formation and blood coagulation, and hemolysis [12]. The occurrence of both should be avoided to ensure long term ventricular support.…”
Section: Introductionmentioning
confidence: 99%
“…Indeed, this regimen has reduced the occurrence of thromboembolism in our animals considerably. Pierce and coworkers, 30 Boretos et a1.,63 and Pierce 64 use heparin for the first five days and then go over to a similar regimen.…”
Section: Artificial Hearts and Assist Devicesmentioning
confidence: 99%