2014
DOI: 10.1007/s00604-014-1419-y
|View full text |Cite
|
Sign up to set email alerts
|

Competitive extraction of Gd(III) into a carbon paste electrode impregnated with a nano-sized Gd(III)-imprinted polymer as a new method for its indirect voltammetric determination

Abstract: We describe an indirect method for the voltammetric determination of Gd(III) ion. It is based on competitive extraction of Gd(III) into an ion-imprinted polymer (IIP) on the surface of a carbon paste electrode (CPE). The nano-sized IIP was synthesized via suspension polymerization in silicone oil and deposited on the CPE. The IIPmodified CPE was then incubated with solutions containing Pb(II) and a solution containing both Pb(II) and Gd(III) ions. The oxidative stripping differential pulse voltammetric signal … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…Several electrochemical sensors for the detection of gadolinium have previously been reported. Voltammetric detection of gadolinium was achieved by the impregnation of nano-sized Gd(III)-imprinted polymer in carbon paste electrodes [ 33 ]. Impedimetric detection of gadolinium was obtained by the modification of gold electrodes with terpyridine ligands [ 34 ].…”
Section: Introductionmentioning
confidence: 99%
“…Several electrochemical sensors for the detection of gadolinium have previously been reported. Voltammetric detection of gadolinium was achieved by the impregnation of nano-sized Gd(III)-imprinted polymer in carbon paste electrodes [ 33 ]. Impedimetric detection of gadolinium was obtained by the modification of gold electrodes with terpyridine ligands [ 34 ].…”
Section: Introductionmentioning
confidence: 99%
“…[3]. Different analytical techniques such as inductively coupled plasma mass spectrometry (ICP-MS) [4][5][6][7][8], electron spin resonance (ESR) [9,10], spectrofluorometry [11,12], electrochemical sensor [13,14,2,15,16] and neutron activation analysis [17] have been performed to determine Gadolinium in various samples. Usage of spectrophotometry for determination of Gd(III) is very suitable because this method is the inexpensive and available in all laboratories.…”
Section: Introductionmentioning
confidence: 99%