2015
DOI: 10.1016/j.ijepes.2015.02.032
|View full text |Cite
|
Sign up to set email alerts
|

Compensation of voltage disturbances using PEMFC supported Dynamic Voltage Restorer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(28 citation statements)
references
References 26 publications
0
26
0
Order By: Relevance
“…Figure 11(a-c) depicts the most popularly use D-STATCOM, DVR and UPQC system configuration which consists of half-bridge inverters [85], [98], [100], [103] in single-phase twowire (1p2w) system to compensate the power quality (PQ) problems by injecting current in case of D-STATCOM, voltage in case of DVR and both in the case of UPQC of the electrical power distribution system. Figure 12 (a-c) and are widely reported in literature [56][57][58][59][60], [70], [104][105][106][107][108][109][110][111][112][113][114][115][116][117][118], [119][120][121][122][123][124][125][126][127][128][129][130], .…”
Section: Single-phase Two Wire (1p2w) Compensating Devicesmentioning
confidence: 93%
See 1 more Smart Citation
“…Figure 11(a-c) depicts the most popularly use D-STATCOM, DVR and UPQC system configuration which consists of half-bridge inverters [85], [98], [100], [103] in single-phase twowire (1p2w) system to compensate the power quality (PQ) problems by injecting current in case of D-STATCOM, voltage in case of DVR and both in the case of UPQC of the electrical power distribution system. Figure 12 (a-c) and are widely reported in literature [56][57][58][59][60], [70], [104][105][106][107][108][109][110][111][112][113][114][115][116][117][118], [119][120][121][122][123][124][125][126][127][128][129][130], .…”
Section: Single-phase Two Wire (1p2w) Compensating Devicesmentioning
confidence: 93%
“…The synchronous reference frame (SRF) theory is developed in time-domain based reference current/voltage generation technique. The SRFT is performing the operation in steady-state or transient state as well as for generic voltage and current and capable of controlling the active power filters in real time system [15] , [18], [20], [21], [27], [28], [51], [54], [57], [58], [76], [77], [82], [104], [106], [111], [115], [120], [121], [125], [127], [128], [130], [131], [133], [134], [137], [141], [142], [150], [153], [155], [160], [167], [177], [178], [179], [180], [182], [187], [189], [190], [195], [204], [203], [207],…”
Section: Synchronous Reference Frame (Srf) Theorymentioning
confidence: 99%
“…They have employed a fast estimation method this will helps to recognize voltage sag in approximately half a cycle. Sundarabalan and Selvi (2015) proposed a DVR for fuel cell stack to the grid with respect to the optimal PI and fuzzy controller. This research presents a novel SRF-PLL which helps to estimate phase and frequency to obtain grid control.…”
Section: Problem Identificationmentioning
confidence: 99%
“…This approach provides the best control performance and less response time compared with conventional PI controller under different disturbance. Sundarabalan and Selvi proposed DVR using real coded genetic algorithm–optimized PI and fuzzy logic (FL) controller for improving power quality. The suggested DVR compensates balanced and unbalanced voltage sag/swell, reduces THD, and reduces injection of active power into the grid.…”
Section: Introductionmentioning
confidence: 99%