1988
DOI: 10.1016/s0099-2399(88)80130-4
|View full text |Cite
|
Sign up to set email alerts
|

Compatibility of accessory gutta-percha cones used with two types of spreaders

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
3

Year Published

1993
1993
2014
2014

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 9 publications
0
5
0
3
Order By: Relevance
“…La correspondencia entre conos y espaciadores puede medirse mediante la comparación de sus longitudes, conicidades y ángulos 2*,15*,16 , realización de moldes de los espaciadores 14 y por la cantidad de gutapercha compactada en el interior del conducto 8 . En nuestro estudio hemos utilizado como medio para establecer las relaciones entre los grupos de gutaperchas y espaciadores la comparación de longitudes o diámetros, al igual que las investigaciones realizadas por Zmener y cols 2* y Hartwell y cols 4 .…”
Section: Discussionunclassified
“…La correspondencia entre conos y espaciadores puede medirse mediante la comparación de sus longitudes, conicidades y ángulos 2*,15*,16 , realización de moldes de los espaciadores 14 y por la cantidad de gutapercha compactada en el interior del conducto 8 . En nuestro estudio hemos utilizado como medio para establecer las relaciones entre los grupos de gutaperchas y espaciadores la comparación de longitudes o diámetros, al igual que las investigaciones realizadas por Zmener y cols 2* y Hartwell y cols 4 .…”
Section: Discussionunclassified
“…1991) however, the dimension and form of gutta‐percha point tips is highly unpredictable, not uniform, and difficult to measure. It has been shown that diameter measurements 1 mm (D 1 ) behind the instrument tip are more practical and equally valid (Jerome et al . 1988).…”
Section: Discussionmentioning
confidence: 99%
“…However, the materials and instruments used to create such fillings must be uniform and compatible with one another if such results are to be reproducible. Jerome et al . (1988), using various combinations of nonstandardized gutta‐percha points and finger spreaders to create root canal fillings, demonstrated that the quality of the seal achieved was related directly to the relationship between finger spreader and gutta‐percha point.…”
Section: Introductionmentioning
confidence: 99%
“…After 30 s, the jig of the Instron machine was released and the spreader removed from the root canal with a back and forth motion. To control rebound of gutta‐percha, no more than 5 s was allowed to elapse after removal of the spreader before placing an accessory cone (Jerome et al. 1988).…”
Section: Methodsmentioning
confidence: 99%