2005
DOI: 10.1016/j.chroma.2004.11.018
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of voltammetric detection assisted by multivariate curve resolution with amperometric detection in liquid chromatographic analysis of cysteine-containing compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 22 publications
(9 citation statements)
references
References 28 publications
0
9
0
Order By: Relevance
“…These results suggested that the developed method for the determination of the six analytes was accurate and sensitive. Compared with other reported methods [27][28][29][30][31], similar response ranges but higher detection limits were achieved with the HPLC-ELSD method compared with the HPLC-fluorescence (Flu) method. However, the HPLC-Flu method has a complicated derivatization process, whereas low detection limits can be obtained with the HPLC-ELSD method relative to the HPLC-ED or ion-pair chromatography (IPC)-MS methods (table 2).…”
Section: Calibration Curves Linear Ranges and Detection Limitsmentioning
confidence: 68%
“…These results suggested that the developed method for the determination of the six analytes was accurate and sensitive. Compared with other reported methods [27][28][29][30][31], similar response ranges but higher detection limits were achieved with the HPLC-ELSD method compared with the HPLC-fluorescence (Flu) method. However, the HPLC-Flu method has a complicated derivatization process, whereas low detection limits can be obtained with the HPLC-ELSD method relative to the HPLC-ED or ion-pair chromatography (IPC)-MS methods (table 2).…”
Section: Calibration Curves Linear Ranges and Detection Limitsmentioning
confidence: 68%
“…For more details about working electrode preparation see ref. [11]. A stainless steel was used as an auxiliary electrode.…”
Section: Instrumentationmentioning
confidence: 99%
“…In those cases the use of a more selective detection plays a crucial role. In previous works [10][11][12], VD-MCR-ALS detection mode has been applied as a first approach to quantify overlapping peaks. Despite its benefits, VD-MCR-ALS owned some shortcomings: i) when compounds with very similar electrochemical responses are analyzed, the potential range where the signals can be resolved is very narrow, and this introduces an important error in the mathematical solution, and ii) the concentrations required for a satisfactory quantization were higher than in AD.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…[1][2][3] So the study of the L-cysteine oxidation and its detection is an important work. To date, many analytical approaches have been developed for L-cysteine detection such as fluorometry based on fluorescent dyes, [4][5][6][7] electrochemical analysis [8][9][10][11] and chromatography separation 12,13 and so on. Compared with other options, electrochemical techniques have the inherent advantages of simplicity, ease of miniaturization, high sensitivity, and relatively low cost.…”
Section: Introductionmentioning
confidence: 99%