2018
DOI: 10.1007/s00405-018-5019-z
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of unidirectional and circumferential manometric measures within the pharyngoesophageal segment: an exploratory study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…With the introduction of circumferentially recording pressure sensors spaced at one‐centimeter intervals, the above‐mentioned technical shortcomings can be overcome, which presents the opportunity to systematically include the manometric evaluation of the UES in clinically performed manometry. Data in this regard are emerging 74–76 and the present study contributes to the fundamental information in this field.…”
Section: Discussionmentioning
confidence: 70%
“…With the introduction of circumferentially recording pressure sensors spaced at one‐centimeter intervals, the above‐mentioned technical shortcomings can be overcome, which presents the opportunity to systematically include the manometric evaluation of the UES in clinically performed manometry. Data in this regard are emerging 74–76 and the present study contributes to the fundamental information in this field.…”
Section: Discussionmentioning
confidence: 70%
“…The paradoxical appearance of P1 will need further investigation in order to either identify a physiological background or find an alternative explanation for its presence. A limitation of the measuring results by using a unidirectional manometric catheter cannot be completely excluded, although the high‐resolution, small‐diameter catheter used here is known to only minimally affect the dynamics of the UES 39,40 . Further limitations are certainly given due to the rather small study population size (n = 7), although experiments were performed repeatedly in each individual.…”
Section: Discussionmentioning
confidence: 97%
“…A limitation of the measuring results by using a unidirectional manometric catheter cannot be completely excluded, although the high-resolution, small-diameter catheter used here is known to only minimally affect the dynamics of the UES. 39,40 Further limitations are certainly given due to the rather small study population size (n = 7), although experiments were performed repeatedly in each individual. On the technical side, droplet formation stability in MIT-LAR should be enhanced as formation of satellite droplets was observed in this study.…”
Section: Limitationsmentioning
confidence: 99%
“…In the esophageal tract, there is evidence of radial symmetry in pressure, and this assumption is no longer valid in correspondence of radially asymmetric structures (e.g., UES and LES): for this reason, it seems reasonable that a circumferential system records more accurate data [56]. Hernandez et al [58] investigated within-subjects differences between unidirectional and circumferential pressure measurements in the pharyngoesophageal segment during swallows: unidirectional data were collected using a standard LRM catheter on 10 healthy subjects. The resulting recorded pressures were compared with circumferentially integrated data collected on the same subjects with a HRM system.…”
Section: High-resolution Manometry (Hrm)mentioning
confidence: 99%