2011
DOI: 10.1007/s00449-011-0577-0
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of two mathematical models for correlating the organic matter removal efficiency with hydraulic retention time in a hybrid anaerobic baffled reactor treating molasses

Abstract: A modelling of the anaerobic digestion process of molasses was conducted in a 70-L multistage anaerobic biofilm reactor or hybrid anaerobic baffled reactor with six compartments at an operating temperature of 26 °C. Five hydraulic retention times (6, 16, 24, 72 and 120 h) were studied at a constant influent COD concentration of 10,000 mg/L. Two different kinetic models (one was based on a dispersion model with first-order kinetics for substrate consumption and the other based on a modification of the Young equ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 35 publications
0
2
0
Order By: Relevance
“…Furthermore, at lower HRT (1 d, OLR = 0.95 kg COD m −3 d −1 ), the VA was high, and the pH was in an acidic range, which could be due to an active decrease of sludge in the reactors. High VA and low pH favor the establishment of the acidogenic phase and prevent the growth of methanogens [44]. The decline in VA at lower OLR (0.25 kg COD m −3 d −1 ) suggests that the anaerobic bacteria were utilizing the feed well.…”
Section: R Shahperi Et Al / Desalination and Water Treatmentmentioning
confidence: 99%
“…Furthermore, at lower HRT (1 d, OLR = 0.95 kg COD m −3 d −1 ), the VA was high, and the pH was in an acidic range, which could be due to an active decrease of sludge in the reactors. High VA and low pH favor the establishment of the acidogenic phase and prevent the growth of methanogens [44]. The decline in VA at lower OLR (0.25 kg COD m −3 d −1 ) suggests that the anaerobic bacteria were utilizing the feed well.…”
Section: R Shahperi Et Al / Desalination and Water Treatmentmentioning
confidence: 99%
“…The waveform and slope partition have extend the flow line remarkably and HRT, avoiding to occurring dead angle. As a result the longer flow line of influent performs a good efficiency [5].The reason is that they have created a good hydraulic condition for the whole system [6]. In addition, it also provides a good living environment for microorganisms which promote the ability of adsorption and degradation of contaminant, so it has fundamentally strengthened the efficiency of the system.…”
Section: Introductionmentioning
confidence: 99%