Comparison of transient severe motion in gadoxetate disodium and gadopentetate dimeglumine-enhanced MRI: effect of modified breath-holding method

Abstract: • The modified breath-holding method significantly reduced the incidence of TSM. • Gadoxetate disodium and gadopentetate dimeglumine showed comparable motion scores. • TSM incidence was comparable between gadoxetate disodium- and gadopentetate dimeglumine-enhanced MRI.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
21
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(23 citation statements)
references
References 27 publications
0
21
2
Order By: Relevance
“…The TSM frequency discovered in our study matched the TSM frequency described previously in the literature [1][2][3][4][5][6][7][8] which corroborates the hypothesis that Gd-EOB-DTPA acts as a chemo-toxic trigger evoking TSM that cannot be willingly mitigated by education and training. Our results differ from the results of Gutzeit et al [18] and Song et al [19]. The authors reduced the incidence of TSM from 13% to 0% (4/30 vs. 0/30 patients) [18] and from 14% to 3.8% (14/100 vs. 3/80 patients) [19] by employing a modified breath-hold command with several breathing cycles prior to imaging.…”
Section: Plos Onecontrasting
confidence: 99%
See 2 more Smart Citations
“…The TSM frequency discovered in our study matched the TSM frequency described previously in the literature [1][2][3][4][5][6][7][8] which corroborates the hypothesis that Gd-EOB-DTPA acts as a chemo-toxic trigger evoking TSM that cannot be willingly mitigated by education and training. Our results differ from the results of Gutzeit et al [18] and Song et al [19]. The authors reduced the incidence of TSM from 13% to 0% (4/30 vs. 0/30 patients) [18] and from 14% to 3.8% (14/100 vs. 3/80 patients) [19] by employing a modified breath-hold command with several breathing cycles prior to imaging.…”
Section: Plos Onecontrasting
confidence: 99%
“…Our results differ from the results of Gutzeit et al [18] and Song et al [19]. The authors reduced the incidence of TSM from 13% to 0% (4/30 vs. 0/30 patients) [18] and from 14% to 3.8% (14/100 vs. 3/80 patients) [19] by employing a modified breath-hold command with several breathing cycles prior to imaging. We speculate that additional The error bars indicate the minimum and maximum RM score and the boxes depict the interquartile ranges demarcated by median scores.…”
Section: Plos Onecontrasting
confidence: 99%
See 1 more Smart Citation
“…Furthermore, since BH-CS-MRCP is a 'breath-hold' examination, the image quality is largely dependent on the patient's compliance as well as the capability to breath-hold. Our MR radiographers are well trained in improving patient compliance, through the provision of good instructions in preparation for breath-holding image acquisition, as previously described [21,22].…”
Section: Discussionmentioning
confidence: 99%
“…In order to solve this problem, several strategies are conceivable. One potential solution can be patient-based: through informing patients concerning the problem of acute transient dyspnea or performing breath-hold practice before the scan, the rate of artifacts could be decreased [8]. Likewise, dilution of the contrast agent is able to reduce the incidence of artifacts [9,10].…”
Section: Introductionmentioning