2003
DOI: 10.5194/acp-3-1409-2003
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of total ozone from the satellite instruments GOME and TOMS with measurements from the Dobson network 1996–2000

Abstract: Abstract. Over the last 3 decades, satellite data have been used to monitor long-term global changes in stratospheric ozone. The TOMS series (1978-present) and GOME (1995-present) are two very important instruments in this context. In this paper, TOMS total ozone and three approaches to derive total ozone from GOME measurements are validated with ground-based Dobson network data. Beyond the operational products of both instruments, e.g. TOMS version 7 and GOME Data Processor version 2.7, total ozone is calcu… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
40
0

Year Published

2004
2004
2018
2018

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 64 publications
(42 citation statements)
references
References 25 publications
(24 reference statements)
2
40
0
Order By: Relevance
“…This data set also showed the highest values for all seasons. TOMS values for all seasons are consistent with the findings of Bramstedt et al (2003). High ozone measurements from the TOMS satellite can also be due to the years of overpass (1978 to 1993) when atmospheric ozone concentrations were relatively high (Bojkov and Fioletov, 1995).…”
Section: Resultssupporting
confidence: 78%
“…This data set also showed the highest values for all seasons. TOMS values for all seasons are consistent with the findings of Bramstedt et al (2003). High ozone measurements from the TOMS satellite can also be due to the years of overpass (1978 to 1993) when atmospheric ozone concentrations were relatively high (Bojkov and Fioletov, 1995).…”
Section: Resultssupporting
confidence: 78%
“…Lambert et al, 1999Lambert et al, , 2000Bramstedt et al, 2003;Balis et al, 2007a, b;McPeters et al, 2008;Koukouli et al, 2012Koukouli et al, , 2015. An "inverse" quality assessment, i.e.…”
Section: Ground-based Network Datamentioning
confidence: 99%
“…Ridolfi et al, 2007;Lambert et al, 2012;Ignaccolo et al, 2015) and for ozone profiles (Sparling et al, 2006;Cortesi et al, 2007), they remain to be quantified for total ozone column (TOC) comparisons. This is the objective of the current paper.…”
mentioning
confidence: 99%
“…The estimated accuracy is about 3 to 5 %. Since 2000, EP-TOMS experienced instrumental problems introducing a 3 % bias in total ozone (Bramstedt et al, 2003). For the version 8, an empirical correction was applied by NASA to overcome this bias (McPeters et al, 2007).…”
Section: Ep-tomsmentioning
confidence: 99%