2014
DOI: 10.21014/acta_imeko.v3i3.94
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of three types of dry electrodes for electroencephalography

Abstract: A potential new area of routine application for electroencephalography (EEG) is the brain-computer interface, which might enable disabled people to interact with their environment, based on measured brain signals. However, conventional electroencephalography is not suitable here due to limitations arising from complicated, time-consuming and error-prone preparation. Recently, several approaches for dry electrodes have been proposed. Our aim is the comparison and assessment of three types of dry electrodes and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

6
27
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 29 publications
(34 citation statements)
references
References 12 publications
(15 reference statements)
6
27
0
1
Order By: Relevance
“…The shape of the dry-contact electrodes must enable the passing through of the hair layer and provide sufficient contact surface, reliability and stability, as well as patient comfort (Fiedler et al 2014). The developed electrode design consists of 24 single conic pins with circular tops of 1 mm in diameter and a height of 6 mm.…”
Section: Dry Electrodesmentioning
confidence: 99%
See 3 more Smart Citations
“…The shape of the dry-contact electrodes must enable the passing through of the hair layer and provide sufficient contact surface, reliability and stability, as well as patient comfort (Fiedler et al 2014). The developed electrode design consists of 24 single conic pins with circular tops of 1 mm in diameter and a height of 6 mm.…”
Section: Dry Electrodesmentioning
confidence: 99%
“…The centerto-center distances of the pins are 2.5 mm. The design is an improved version of our previously presented multipin electrodes (Fiedler et al 2014;Pedrosa et al 2015a).…”
Section: Dry Electrodesmentioning
confidence: 99%
See 2 more Smart Citations
“…Diversas topologias para eletrodos ativos têm sido sugeridas, com o objetivo de contornar este problema [1], [5], [6], [7], [8]. O maior esforço está em otimizar o circuito, sendo poucos estudos focados na influência do material na qualidade do sensor, embora a interface do eletrodo/pele seja o real fator limitante para os sistemas com eletrodos ativos [9].…”
Section: Introductionunclassified