2013
DOI: 10.1016/j.jpba.2012.03.020
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of three immunosensor methods (surface plasmon resonance, screen-printed and classical amperometric immunosensors) for immunoglobulin G determination in human serum and animal or powdered milks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 33 publications
(36 reference statements)
0
9
0
Order By: Relevance
“…Microscopic observation revealed that IgG promoted aggregation of S. aureus in LB, whereas no significant increase in aggregation was observed in media supplemented with lactoferrin or BSA. The mean IgG concentration in healthy bovine milk samples is 0.45-1.34 mg ml −1 , significantly smaller than the value in mastitic milk, 3-15 mg ml −1 [22]. Based on these observations, we hypothesized that the size of S. aureus aggregates changes according to the concentration of IgG in the bovine udder.…”
Section: Aggregation Of S Aureus In the Presence Of Milk Componentsmentioning
confidence: 93%
“…Microscopic observation revealed that IgG promoted aggregation of S. aureus in LB, whereas no significant increase in aggregation was observed in media supplemented with lactoferrin or BSA. The mean IgG concentration in healthy bovine milk samples is 0.45-1.34 mg ml −1 , significantly smaller than the value in mastitic milk, 3-15 mg ml −1 [22]. Based on these observations, we hypothesized that the size of S. aureus aggregates changes according to the concentration of IgG in the bovine udder.…”
Section: Aggregation Of S Aureus In the Presence Of Milk Componentsmentioning
confidence: 93%
“…The use of the extended spacer arm greatly improves the interaction between extravidin and the biotinylated macromolecule, thus overcoming the steric hindrance present at the biotin binding sites of extravidin [ 32 ]. Detailed descriptions of this technique were reported in previous papers [ 23 , 24 , 25 , 26 ].…”
Section: Resultsmentioning
confidence: 99%
“…Our research group has worked on inhibition biosensors, in particular tyrosinase biosensors, designed to analyse triazine and benzotriazine compounds [ 19 , 20 ]. In recent years, our team has investigated the development of conventional immunosensors [ 21 , 22 , 23 , 24 ], or screen-printed methods [ 25 , 26 ] above all because they were found to be more selective for the different classes of pesticide. In this framework the aim of the present research was to compare the analytical features of a new SPR device with two conventional or screen-printed amperometric immunosensor devices.…”
Section: Introductionmentioning
confidence: 99%
“…Bioaffinity sensors with a pre-formed metastable ligand-receptor complex that are homologus to the enzyme immunosensor have been used in the determination of thyroxine (T4), biotin and insulin. [404142]…”
Section: Types Of Cell-based Biosensorsmentioning
confidence: 99%