Comparison of the ViOptix Intra.Ox Near Infrared Tissue Spectrometer and Indocyanine Green Angiography in a Porcine Bowel Model

Abstract: Background This study aims to directly compare measurements of tissue oxygenation obtained using the Intra.Ox (Vioptix Inc., Fremont, CA) near infrared spectrometer with the perfusion assessment of the indocyanine green (ICG)-based SPY Elite imaging system (Stryker Co., Kalamazoo, MI) in a porcine bowel model. Methods Two live minipigs underwent laparotomy and isolation of a 30-cm segment of a large bowel. Standardized oximetry measurements were taken along the segment of bowel immediately before, af… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…Furthermore, this technique has only been previously described in an animal model, allowing much greater ischaemia than experienced clinically [ 38 ]), while mitochondrial respiration assessment necessitates full thickness biopsies. Non-invasive tissue oxygen saturation hyperspectral oximetry measurement [ 39 ] has potential but is still of uncertain clinical relevance and there is currently no CE-marked device for use in Europe [ 40 , 41 ].…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, this technique has only been previously described in an animal model, allowing much greater ischaemia than experienced clinically [ 38 ]), while mitochondrial respiration assessment necessitates full thickness biopsies. Non-invasive tissue oxygen saturation hyperspectral oximetry measurement [ 39 ] has potential but is still of uncertain clinical relevance and there is currently no CE-marked device for use in Europe [ 40 , 41 ].…”
Section: Discussionmentioning
confidence: 99%
“…Intraoperative monitoring of renal allograft reperfusion was performed using a handheld, non-invasive, and FDA-approved NIRS tissue oximetry sensor device (Intra.Ox, ViOptix, Inc. Newark, CA, USA) that can provide real-time and instantaneous rSO 2 measurements [ 16 , 18 ]. During the surgical procedure, rSO 2 levels were measured pre- and post-reperfusion (i.e., removal of vascular clamps) at 3, 5, 10, and 20 min by placing the device directly over three regions of the allograft: upper pole (UP), renal hilum (RH), and lower pole (LP).…”
Section: Methodsmentioning
confidence: 99%
“…Despite the proven benefits, the utilization of NIRS devices to monitor allograft perfusion has not been investigated intraoperatively because of their inconveniently bulky size and in adult KT due to the large skin-to-kidney distance [ 15 ]. A wireless, non-invasive, and handheld NIRS device was recently developed and approved by the FDA; however, its use has only been studied in porcine skin flap and bowel models [ 16 , 17 , 18 ] to our knowledge.…”
Section: Introductionmentioning
confidence: 99%
“…A recent study has presented encouraging first data supporting the use of Intra.OxÔ for intraoperative tissue oxygenation measurements following large bowel resection and vessel ligation in a porcine model. 22 However, only 2 animals were included, and intestinal anastomoses were not conducted in that study. In a more comprehensive approach, we implemented a large-scale porcine model mimicking critical ischemia in the small bowel to investigate both the applicability and efficacy of Intra.-OxÔ in assessing intestinal tissue perfusion and exploring the association between low StO 2 and AL following intestinal anastomosis.…”
Section: Introductionmentioning
confidence: 99%