Comparison of the Tono-Pen to the Goldmann Applanation Tonometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

10
63
4
5

Year Published

1991
1991
2014
2014

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 152 publications
(82 citation statements)
references
References 9 publications
10
63
4
5
Order By: Relevance
“…The Tono-Pen XL ® tonometer has been used for more than 3 decades, and although it is the most popular tonometer in veterinary medicine, its accuracy has always been questioned in human medicine (FRENKEL et al, 1988;IESTER et al, 2001;ANDRADA MÁRQUES et al, 2003;KALESNYKAS & UUSITALO, 2007). In addition, its high cost has restricted its use to specialized veterinary ophthalmology centers.…”
Section: Discussionsupporting
confidence: 41%
“…The Tono-Pen XL ® tonometer has been used for more than 3 decades, and although it is the most popular tonometer in veterinary medicine, its accuracy has always been questioned in human medicine (FRENKEL et al, 1988;IESTER et al, 2001;ANDRADA MÁRQUES et al, 2003;KALESNYKAS & UUSITALO, 2007). In addition, its high cost has restricted its use to specialized veterinary ophthalmology centers.…”
Section: Discussionsupporting
confidence: 41%
“…A raised IOP in upgaze should alert the examiner of likely muscle restriction, rather than using subjective forced duction testing. 33,35 We had no direct surgical complications in this study, although we did observe persistent new-onset diplopia at 6 months post decompression in 2 (6.1%) patients, which is similar to other reports. [36][37][38][39][40] This audit was of a prospective design but not blinded and this should be recognised, along with the limitations that this carries.…”
Section: Discussionmentioning
confidence: 46%
“…After penetrating keratoplasty, Viestenz found that DCT yielded reproducible IOP values that were higher in comparison to those for GAT, and were disturbed by postoperative intrastromal sutures [19]. The Tono-Pen ® XL (TP) is a handheld tonometer operating on the same principle as the Mackay-Marg tonometer [12]. The accuracy of the TP is still a matter of discussion.…”
Section: Discussionsupporting
confidence: 42%
“…The Tono-Pen ® XL (TP; the way it works has been detailed elsewhere [12]) performs four independent IOP readings and provides a reliability index for each single measurement. Measurements were only used if the scatter index was below 5%.…”