2021
DOI: 10.1155/2021/2959055
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the Accuracy of Fixture-Level Implant Impression Making with Different Splinting Techniques

Abstract: Objectives. The impression-taking technique is one of the most critical factors that not only prevents the shrinkage caused by polymerization but also enhances the accuracy of implant impressions. Also, choosing the right time of taking impressions after splinting implants is one of the important criteria that affects the impression-taking technique. Accordingly, the present study aimed to evaluate the accuracy of different splint methods for implant impressions made at different times. Methods. In this in vit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…The resin matrix of the filler-loaded PMMA-based resin was prepared from appropriate amounts of pre-polymerized PMMA powder, MMA, EGDMA cross-linker, and BAPO photo-initiator. This system is similar to the powder–liquid mixtures used in many commercial self-cured acrylic resin systems [ 35 , 36 ]. In our system, the EGDMA cross-linker creates a three-dimensional polymer network with the MMA monomer via free-radical polymerization by light irradiation [ 37 ].…”
Section: Discussionmentioning
confidence: 99%
“…The resin matrix of the filler-loaded PMMA-based resin was prepared from appropriate amounts of pre-polymerized PMMA powder, MMA, EGDMA cross-linker, and BAPO photo-initiator. This system is similar to the powder–liquid mixtures used in many commercial self-cured acrylic resin systems [ 35 , 36 ]. In our system, the EGDMA cross-linker creates a three-dimensional polymer network with the MMA monomer via free-radical polymerization by light irradiation [ 37 ].…”
Section: Discussionmentioning
confidence: 99%
“…Accurate impressions and the correct transfer of implant position to the cast are highly significant. 1 , 2 In this regard, one of the main studied areas is improving the accuracy and adaptation of implant-based prostheses as well as the accuracy of impression making. Accordingly, this includes the promotion of restorative clinical methods and the quality of materials used during the implant prosthesis steps.…”
Section: Introductionmentioning
confidence: 99%
“…7 Most earlier reports have supposed that the splint method is more accurate during implant impression with internal connections. 1 …”
Section: Introductionmentioning
confidence: 99%