38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003.
DOI: 10.1109/ias.2003.1257499
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of state-of-the-art voltage source converter topologies for medium voltage applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
33
0

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 60 publications
(35 citation statements)
references
References 9 publications
2
33
0
Order By: Relevance
“…A comparison on THD of 2L-VSI, 3L-NPC and matrix converter with PMSG is undertaken in [51] and 3L-NPC provides the lowest value of THD among the three topologies. This result verifies that THD decreases with increasing number of levels [46]. Different PEC topologies consist of components with variable numbers and sizes that result variation in cost.…”
Section: Discussion On Pecsupporting
confidence: 48%
See 2 more Smart Citations
“…A comparison on THD of 2L-VSI, 3L-NPC and matrix converter with PMSG is undertaken in [51] and 3L-NPC provides the lowest value of THD among the three topologies. This result verifies that THD decreases with increasing number of levels [46]. Different PEC topologies consist of components with variable numbers and sizes that result variation in cost.…”
Section: Discussion On Pecsupporting
confidence: 48%
“…In terms of power losses, it is widely reported that ML VSCs have less power losses than 2L VSIs with 3-Level Neutral Point Clamped VSIs (3L-NPC) having even lower amount of losses over 3-Level Flying Capacitor VSIs (3L-FLC) [46][47][48]. This advantage of 3L-NPC, however, inherits poor power loss distribution, which is the main drawback of 3L-NPC as mentioned previously.…”
Section: Discussion On Pecmentioning
confidence: 97%
See 1 more Smart Citation
“…The power converters are based on two-level voltage-source converter (VSC) topology [52] and have been manufactured by Belgian company Triphase [53]. Each converter is additionally fitted out with an auxiliary diode rectifier and a step-up transformer that enable to feed the converter DC-bus in order to operate as a power source.…”
Section: Smart Energy Integration Labmentioning
confidence: 99%
“…Multilevel inverters have become the dominant solution for high power electrical drives [1], [2], [3], [4]. Moreover, the three-phase, three-level neutral-pointclamped voltage-source converter (3L-NPC VSC) is one of the most used converters for medium voltage drives [3], [2], [1], [5].…”
Section: Introductionmentioning
confidence: 99%