2018
DOI: 10.1016/j.marpolbul.2018.04.056
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of six digestion methods on fluorescent intensity and morphology of the fluorescent polystyrene beads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(12 citation statements)
references
References 42 publications
0
12
0
Order By: Relevance
“…Only peaks diagnostic for PS bonds susceptible and indicative of polymer reactivity (i.e., aromatic and aliphatic bonds) were monitored. [1,17,26,28] PL was used to analyze the fluorescence intensity of MPs pre-and postdigestion. MPs (n = 3) were dissolved in THF in a ratio such that the optical density (OD) of the solution was 1 ± 0.01 at an absorbance wavelength 257 nm.…”
Section: Spectral Analysesmentioning
confidence: 99%
See 2 more Smart Citations
“…Only peaks diagnostic for PS bonds susceptible and indicative of polymer reactivity (i.e., aromatic and aliphatic bonds) were monitored. [1,17,26,28] PL was used to analyze the fluorescence intensity of MPs pre-and postdigestion. MPs (n = 3) were dissolved in THF in a ratio such that the optical density (OD) of the solution was 1 ± 0.01 at an absorbance wavelength 257 nm.…”
Section: Spectral Analysesmentioning
confidence: 99%
“…[ 28 ] Similarly, PL has been used to infer polymer degradation by measuring fluorescence quenching of the incorporated dye. [ 17 ] Another lesser used quantitative method, often employed by polymer scientists and engineers, is gel permeation chromatography (GPC), which analyses the average molecular weight distribution. This technique provides direct evidence of polymer chain degradation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Our previous study has found that three fluorescent polystyrene MPs in biological samples could be extracted with KOH without changing the characterization of the MPs [9]. As shown in figure 2, there was a clear correlation between the concentrations of the MPs and fluorescence intensity, with R 2 of 0.9996, 0.9939 and 0.9951, respectively.…”
Section: Determination Of Microplastic Detection Methodsmentioning
confidence: 84%
“…PS-NP distribution in parental tissues and offspring was observed using tissue sections combined with fluorescence microscopy (Eclipse 80i, Nikon, Tokyo, Japan) and fluorescence microscope alone, respectively. The quantitative determination of PS-NPs was carried out by KOH digestion 42 and fluorescence spectrophotometry. The mean recoveries of PS-NPs ranged from 80% to 89%.…”
Section: Quantification Of Ehs and Ps-nps In F0 And F1 Eggsmentioning
confidence: 99%