2008
DOI: 10.1007/s00198-008-0820-y
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of QCT-derived and DXA-derived areal bone mineral density and T scores

Abstract: This study shows that results from QCT aBMD appropriately adjusted can be evaluated against NHANES reference data to diagnose osteoporosis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
107
1
3

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 154 publications
(116 citation statements)
references
References 13 publications
5
107
1
3
Order By: Relevance
“…Unfortunately, therefore, DEXA scans cannot be used as a practical routine postoperative evaluative tool. Third, while the majority of DEXA scans were performed at one center with one type of DEXA scanner (Hologic TM QDR4500), the second site employed a different type of scanner (GE Lunar Prodigy), which can introduce a potential evaluation error [21,23]. However, we evaluated changes in bone density from baseline and each patient served as his/her own control in this study design.…”
Section: Discussionmentioning
confidence: 99%
“…Unfortunately, therefore, DEXA scans cannot be used as a practical routine postoperative evaluative tool. Third, while the majority of DEXA scans were performed at one center with one type of DEXA scanner (Hologic TM QDR4500), the second site employed a different type of scanner (GE Lunar Prodigy), which can introduce a potential evaluation error [21,23]. However, we evaluated changes in bone density from baseline and each patient served as his/her own control in this study design.…”
Section: Discussionmentioning
confidence: 99%
“…Nonetheless, the standard of osteoporosis based on T score by DXA was used in most QCT studies [19][20][21][22]. The American College of Radiology (ACR) has published guidelines for the performance of QCT in lumbar spine in 2008 and amended in 2014.…”
Section: Qct Technique In the Lumbar Spinementioning
confidence: 99%
“…The QCT X-Ray Absorptiometry (CTXA) analysis at the hip using pelvis CT images with a calibration phantom and software system was developed by Cann et al (Mindways Software, Inc, Austin, TX) [13,20]. This technique uses a two-dimensional projection (anterior-posterior) of CT three-dimensional formation with software to calculate the area bone density (mg/cm 2 ) in hip and femoral neck integral bone, just like the DXA method.…”
Section: Hip Area Bmd Measurement By Ct Two-dimensional Projection Immentioning
confidence: 99%
See 2 more Smart Citations