2013
DOI: 10.1061/(asce)em.1943-7889.0000441
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of NDT Methods for Assessment of a Concrete Bridge Deck

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
49
0
8

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 94 publications
(60 citation statements)
references
References 5 publications
0
49
0
8
Order By: Relevance
“…Gucunski et al [5] and Oh et al [18] compared efficiencies of different NDE methods at an in-service bridge. In their comparative studies, they used several types of hardware for IE and GPR, and obtained different results depending on their devices.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Gucunski et al [5] and Oh et al [18] compared efficiencies of different NDE methods at an in-service bridge. In their comparative studies, they used several types of hardware for IE and GPR, and obtained different results depending on their devices.…”
Section: Literature Reviewmentioning
confidence: 99%
“…A termografia passiva não requer fontes de estimulação externa (Oh et al, 2013), usa a energia solar e a temperatura ambiente como principais recursos de aquecimento, e é a técnica utilizada para inspeção de pontes (Kee et al, 2012;Vaghefi et al, 2012;Alfredo-Cruz et al, 2015), bem como para outras estruturas e outros campos (Buyukozturk, 1998;Lahiri et al, 2012;Barreira;Almeida;Delgado, 2016;Fox;Goodhew;Wilde, 2016;O'Grady;Lechowska;Harte, 2016). Em contraste, a termografia ativa requer fontes externas de estimulação de calor (Kee et al, 2012;Rehman et al, 2016), pode até ser sub-dividida de acordo com a natureza da estimulação como: Pulsed, Lock-in, Pulsed-Phase, entre outros (Maldague, 2001).…”
Section: Metodologia E Análiseunclassified
“…A termografia infravermelha é uma técnica muito sensível em relação às condições ambientais (Yehia et al, 2007;Oh et al, 2013). A exposição ao sol é considerada como a principal força para gerar gradientes térmicos, pois afeta os valores de temperatura medidos, gerando energia térmica na superfície do concreto.…”
Section: Inspeção De Pontesunclassified
“…The IE method has been set up as a reliable NDT technique for detecting delamination and recognizing measurements of defects in concrete constructions, especially in decks and pavements [2]. One of the main advantages of the IE is that it is sufficient to access from one side to that of the structure to perform tests [3] which greatly facilitate research in the road facilities or places difficult to diagnose e.g., dams or sub-structures.…”
Section: Impact Echo and Air-coupled Impact-echo Methods Of Ndtmentioning